background image

MOVING SYSTEMS

SAFETY SYSTEMS

GATES

VIDEO DOORS

LIBRETTO ISTRUZIONI - INSTRUCTION MANUAL

3

LIMITI DI UTILIZZO - LIMITATIONS OF USE:

MODELLO

MODEL

LUNGHEZZA (metri)

LENGTH (metres)

PESO (Kg)

WEIGHT (kg)

SW250

2

350

SW250

2,5

300

SW350

2,5

350

SW350

3

300

SW350

3,5

250

2

GENERAL DESCRIPTION: electro-mechanical geared motor designed to automate residential-type hinged 

gates. The geared motor is irreversible and keeps the gate locked during opening and closing. The installation of 

an electric lock is recommended only for leaves exceeding 2.5 metres. The geared motor does not have a me-

chanical clutch. For this reason, it must be controlled by a control unit with torque adjustment.

The REA series geared motors are available in the RIGHT and/or LEFT version depending on the leaf on which 

it is applied. The leaves must be looked at from the inside.

When choosing the geared motor to be installed, the weight and length of the leaf on which it is installed must 

be assessed (see limitations of use).

Before starting installation, check the sturdiness of the structure (hinged columns and mechanical stops). The 

mechanical stops need to be installed on the opening and closing if the gate does not have mechanical stops or if 

these are damaged.

3

CARATTERISTICHE TECNICHE - TECHNICAL CHARACTERISTICS:

Modello

Grado di 

protezione

Peso 

(Kg)

Alimenta-

zione 

Assorbi-

mento

Potenza

Intermitten-

za di lavoro

Spinta

Tempo di 

apertura

Condensatore Temperatura 

di esercizio

Model

Protection 

rating

Weight 

(kg)

Power 

supply

Current Power

Duty cycle Push

Travel 

time

Capacitor

Temperature 

range

SW250 IP44

6

230VAC 1,2A

280W 40%

3200N 23 sec. 8UF

-20/+55°C

SW350 IP44

8

230VAC 1,2A

280W 40%

3200N 34 sec. 8UF

-20/+55°C

4

DIMENSIONI MECCANICHE - MECHANICAL DIMENSIONS:

83 mm

170 mm

SW250 = 730 mm

SW350 = 930 mm

SW250 = 400 mm

SW350 = 600 mm

Figura 1

Figure 1

Summary of Contents for SW250

Page 1: ...LIBRETTO ISTRUZIONI INSTRUCTION MANUAL SW250 SW350 MOVING SYSTEMS SAFETY SYSTEMS GATES VIDEO DOORS ISSW250 ver 1 1 2014 07 01 REA...

Page 2: ...enda dei simboli presenti nel manuale Key of the symbols in this manual PREMESSA AL MANUALE ISTRUZIONI nel corso delle operazioni di assemblaggio e montaggio e collaudo dell automa tismo si possono ve...

Page 3: ...tice and the domestic laws in force The manufacturer of the motor unit cannot be held liable for poor construction of the structure to be motorised or for damage caused during use Incorrect installati...

Page 4: ...s must be looked at from the inside When choosing the geared motor to be installed the weight and length of the leaf on which it is installed must be assessed see limitations of use Before starting in...

Page 5: ...e di X uguale a Y si ha una velocit costante su tutta la corsa del cancello La somma della quota X e Y non deve mai superare la corsa massima utile del motori duttore 360 mm per SW250 e 560 mm per SW3...

Page 6: ...one in the sumps and the wires entering the container of the control unit must be inserted using approved cable glands in keeping with the IP protection of the container DESCRIZIONE INSTALLAZIONE INST...

Page 7: ...ance between the control unit and the electric motor exceeds 10 meters the motor is supplied with a 1 meter cable Lubrificare tutti i perni anteriori e posteriori installare il motoriduttore prestando...

Page 8: ...esso inerenti I bambini non devono giocare con l automazione La pulizia e la manutenzione destinata ad essere effettuata dall utilizzatore non deve essere effettuata da bambini senza sorveglianza I ba...

Page 9: ...e a routine maintenance schedule as required in accordance with the applicable standards within the EEC Machine Direc tive 2006 42 EEC Perform correct routine maintenance referring to the maintenance...

Page 10: ...NI INSTRUCTION MANUAL REGISTRO MANUTENZIONE MAINTENANCE REGISTER 9 DATA DATE MANUTENZIONE ORDINARIA ORDINARY MAINTENANCE MANUTENZIONE STRAORDINARIA EXTRAORDINARY MAINTENANCE DESCRIZIONE INTERVENTO WOR...

Page 11: ...LIBRETTO ISTRUZIONI INSTRUCTION MANUAL 10 COMPOSIZIONE IMPIANTO SYSTEM COMPOSITION CODICE CODE DESCRIZIONE DESCRIPTION QUANTIT QUANTITY NOTE E PARTICOLARI DELL IMPIANTO NOTES AND SYSTEM PARTS...

Page 12: ...inenti 89 336 CEE 93 68 CEE CE DECLARATION OF CONFORMITY SW250 and SW350 The geared motor for 230VAC hinged gates conforms to the following standards 89 336 EEC 93 68 EEC Via Antonio Ferrero 9 Padova...

Reviews: