30
7.1.5
Configuring the Battery
Step
Description
1
In the main menu go to "DEVICE" and then press
"Settings" and "Battery"
2
Press "Battery type" and select "Li-Ion RCT Power"
or the corresponding battery type to be used in your
system.
3
Turn on the battery by setting the battery ON/OFF
switch to position "1".
4
The Inverter checks the battery specifications and
then connects to the battery.
Current sensors are then being tuned in.
The Inverter will then reset and store the settings.
Battery calibration will start.
This can take several hours. (Power from the mains
might be used to assist the calibration in case the PV
Power is insufficient.)
The system will switch automatically into
compensation mode once the calibration has been
completed.
5
Check whether the power sensor has been tuned in.
Select "ONLINE" in the App's main menu. Press the
„
“ symbol,
A list will be displayed.
The value for
"Current sensors are tuned" should be = "1"