6
Fig. 3-3 Product specification
Pos
Description
Comment
1
LCD Operating Display
Displays important Inverter status and operational information (see
section 7.3)
2
Battery connection area
Battery connections (see sections 5.1 to 5.4)
3
RJ45-CAN bus communication
connectors
RJ45-sockets for CAN-bus connection with batteries, Power Sensor
and Power Switch
4
DC load break switch
Normal operation: Switch is in position "1", Turning switch to position
"0" shuts down the inverter.
5
DC connectors
Two separate Solar generator inputs (A & B),
Connector Plug Type : Weidmüller WM4
6
LAN-RJ45
RJ45- socket for connection to router (LAN)
7
Connection area additional
communication
Cable entry for the communication connections on the I/O-curcuit
board (see sections 5.1 to 5.4)
8
AC-connection
AC-connection cable entry
9
Type Plate
Contains technical data, serial number barcode and warning symbols
10
Additional protective
conductor connection
Connection for additional protective conductor (see section 5.6)