![RCT Power Storage DC 10.0 Manual Download Page 34](http://html1.mh-extra.com/html/rct/power-storage-dc-10-0/power-storage-dc-10-0_manual_1424355034.webp)
29
7.1.4
Setting Solar plant peak power and External power reduction
In order to obtain the maximum yield from the solar system, it is possible to configure a dynamic power reduction. There is
no additional equipment required for this configuration apart from the Power Sensor.
The feed-in power is measured at the mains connection point and is only capped if the excess power exceeds the set value.
Step
Description
1
In the RCT Power APP tap on “DEVICE“
-->
“Settings“
--
> “Device settings“
2
Enter the desired values for
“External power reduction based on solar plant peak power [0;1]“
and
“Solar plant peak power [Wp].
Please ensure that you confirm your entries on the keypad. (Depending on your mobile device this requires a
tap on “Enter“ or“OK“).
The input area will briefly turn red before returning to the standard background colour.
Please note: If your system contains
several devices
you must the enter
peak power
of the
combined system.
Enter:
Solar plant peak power
[Wp]
Enter
:
External power reduction
based on solar plant peak
power: e.g. 70% (
≙
0,70)
APP calculates
:
Max. allowed grid feed-in
power [W]