EPSILON ES2,ES4
45
+1
1
00h…FFh
Network address of the
sender
+2
1
4Fh
Command code
+3
1
00h или 01h
Return code: 00h -
command is complied
successfully, 01h -
Error
+4
1
00h…FFh
CRC8
A2.3.2
Support for symbol protocol LLS.
A2.3.2.1
Format of data output (example):
F=FFFF t=1A N=03FF.0<CR><LF> , where:
F – 16-bit code of measured capacity.
t – temperature, °C
N – user code of the measured capacity (always 10 bits despite the parameter set by command
55h).
A2.3.2.2
Supported commands of symbol protocol LLS.
DO
– request for one-time data output. At the moment of receiving this command FLS shows
data 1 time in the format described in P 5.1.
DP
– switching on of periodic data output. This command is sent only once, after which FLS
shows data in the format described in Section 5.1., with interval set by command 54h. This
mode does not depend on the resolution of periodic data output set by command 55h and is
stored until receiving any valid command of EDE protocol or to the turning off and restart of
FLS.
For work with a symbol protocol, bit 1 must be installed in the parameter of command 55h.
Otherwise, commands
DO
and
DP
are ignored, and the periodic data output, if installed, is
made in a binary format in accordance with p.4.1.2.