EPSILON ES2,ES4
41
1
Symbol protocol LLS
0: denied
1: allowed
0 (denied)
Value by
default can be
changed
according to
order
0
Periodic data output after
restart
0: OFF
1: ON
0 (OFF)
Value by
default can be
changed
according to
order
NOTES.
Setting of exchange speed and resolution of data output in symbol format is used in FLS ES2,
ES4 with software versions 1.8 and higher, as well as in ES2X, ES2XL, ES2XXL, ES4X,
ES4XL, ES4XXL with embedded software versions: 4.6, 4.7, 4.10 and higher.
Periodic data output mode is used in ES2, ES4 with software versions: 1.3, 1.4, 1.7 and higher,
as well as in ES2X, ES2XL, ES2XXL, ES4X, ES4XL, ES4XXL with embedded software
versions: 4.6, 4.7, 4.10 and higher.
For ES2, ES4 with software versions 1.3, 1.4, ; bits 1 ... 6 in the command parameter must be
equal to 0.
A2.3.2.1.8
Setting of network address (command 56h).
Command is designed for setting of network address of FLS for work of several fuel level
sensors on one line.
Command format:
Drift, byte
Size of field, byte
Value
Description
0
1
31h
Prefix
+1
1
00h…FFh
Network address of
acceptor
+2
1
56h
Command code
+3
1
00h…FFh
New network address of
FLS
+4
1
00h…FFh
CRC8
Answer format:
Drift, byte
Size of field, byte
Value
Description
0
1
3Eh
Prefix
+1
1
00h…FFh
Network address of
sender
+2
1
56h
Command code
+3
1
00h or 01h
Return code: 00h -
command is complied
successfully, 01h -
Error
+4
1
00h…FFh
CRC8
A2.3.2.2 Special commands for FLS models ES2-0800, ES4-0800.
A2.3.2.2.1
Rough calibration (command 45h).