APPENDIXES
Appendix 1
Software Application "eS Install" (v. 1.0.1.18)
The software application "
eS Install
" (hereinafter - the Program) is designed to provide
calibration process of a fuel tank and to make a calibration table that describes the dependence
of the output code of the sensor on the fuel level.
The program is included to users software (SW), supplied on compact-disk (name ES.000
CD1). To install on a personal computer (PC) it is enough to copy the program into the desired
folder. In addition, ports RS-485 (for a model eS4) or RS-232 (model eS2) must be installed on
PC For a laptop it is recommended to use converters MOXA: USB/RS-485 UPort 1130 or
USB/RS-232 UPort 1110.
To get started with the program you need to connect the sensor to correct port (complying the
polarity of interface and the supply conductors) and provide sourcing of the sensor from an
onboard network of the vehicle or from an external source (power settings - in accordance with
Table 1 of section 3 of this manual).
After launch, in the window "eS Install" you have to select the desired COM port and set the
exchange speed. By default, the sensor with factory settings has the exchange speed of 19200.
Windows RTS and DTR you have to leave unchecked (engineering view).
In the same window there are available menu options such as "Файл (File)", "Опции (Options)",
"Вид (Type)" and «Help» (their purpose is described below).
At the bottom of the window the status of the port is displayed:
If you see message
"Port is closed"
you have to press active bottom
and
program is ready for use.
“COM port N 5 is open“
this message means that COM port is open and works correctly.
“Error in port 257 opening”
- message indicates that the COM port is opening with an
error. In this case, you should check and set up the functionality of the port on the level of
drivers or check the condition of the COM port itself.
For beginning of the process (calibration), press the button
.
The presence of the symbol "Search", marked by the frame in the picture above, shows that a
device (sensor) is not connected to the specified COM port.
In case of normal program start the tab “Information” will be shown.