EPSILON ES2,ES4
39
+1
1
00h…FFh
Network address of
acceptor
+2
1
50h
Command code
+3
1
00h…FFh
CRC8
Answer format:
Drift, byte
Size of field, byte
Value
Description
0
1
3Eh
Prefix
+1
1
00h…FFh
Network address of
sender
+2
1
50h
Command code
+3
2
Vcc=0000h…7FFFh
Formula evaluation of
supply voltage:
U=Vcc/4667,8.
+5
1
00h…FFh
CRC8
A2.3.2.1.6
Installing of the period of data output (command 54h).
The command is designed for setting of period of data output.
Command format:
Drift, byte
Size of field, byte
Value
Description
0
1
31h
Prefix
+1
1
00h…FFh
Network address of
acceptor
+2
1
54h
Command code
+3
1
00h…FFh
Value of the period of data
output -1 s
+4
1
00h…FFh
CRC8
Answer format:
Drift, byte
Size of field, byte
Value
Description
0
1
3Eh
Prefix
+1
1
00h…FFh
Network address of
sender
+2
1
54h
Command code
+3
1
00h or 01h
Return code: 00h -
command is complied
successfully, 01h -
Error
+4
1
00h…FFh
CRC8
A2.3.2.1.7
Installing of data output mode (command 55h).
The command is designed for setting of following parameters: data output capacity (10 or 12
bits), periodic data output (On/Off), resolution