NoKey Force – Installing and Operating
Installing the outer and inner unit
21
4.16
Fold the cable double and place it under
the load holder.
Insert the batteries (5 x AA) into the
battery compartment.
4.17
To define the length of the knob pin:
A
Insert the pin towards the lock
housing until it reaches the
bottom.
B
Measure distance ‘A’.
C
Cut the pin to measurement ‘A’ +
at least 1 mm, but always to one
of the cutting guides 1 – 5.
How to cut