Date Feb. 10, 2016
page 1 of 3
Mounting instructions 70040 VAROS
These mounting instructions are the basis for various approvals, e.g. ECBS, VdS, A2P (CNPP), DNV, UL or others. The
installation of the lock has to be performed in accordance with these instructions. Guidelines of the national certification bodies
are to be considered and complied with.
The lock must be installed by authorized and trained personnel only. The perfect function of the lock and of any additionally
connected or triggered systems (e.g. bolt works) has to be ensured and checked by specialists during the installation of the
lock.
The lock can be mounted in the following positions:
mounting positions of the lock
Bolt left, key hole horizontal
Bolt up, key hole vertical
Bolt down, key hole vertical
optional lock version, no standard
Bolt right, key hole horizontal
Any changes to the lock or key are prohibited as they may result in a malfunction and will void all warranty claims.
Keep the lock mechanism free from dirt and metal chips.
Lock fastening: Use M6 steel socket head cap screws or BSW ¼" steel bolts. The length of engagement must correspond
to the applicable standards considering the thickness of the lock body of 30 mm. Mounting screws: minimum class 4.8 and
maximum class 8.8.
The screws have to be secured either by lock washers, flat springs, tooth lock washers or fan type lock washers or by
gluing.
Screw fixing torque: minimum 5 Nm (44 lb
F
in) and maximum 6 Nm (53 lb
F
in).
The bolt must be able to move freely after the installation of the lock.
For the installation of the lock, we highly recommend to also use the Kaba Mauer key escutcheon as well as the Kaba
Mauer key guiding tube.
For the installation of the lock and the lock accessories take care that the corresponding surfaces of the secure storage
unit are flat and even and that all holes are free of burrs.
During and after installation of the lock and lock accessories take care that the key can easily be inserted into the lock and
turned with minimal force and without binding.
It is recommended, that unauthorized persons have no access to security sensitive parts of the lock, also the door of the
safe, where the lock is installed, is open.
Installation:
Install the lock following the given footprint (sketch 1).