Operator Unit 130-626.NG002
Standard 22 GYRO COMPASS
2-22
8.
Edit the first Deviation Table as described in 2.9.5.
9.
Leave the service mode.
10. Turn the change over switch to activate the second distribution unit.
11. Repeat the whole process to edit the Deviation Table as described in 2.9.5 for the
second magnetic compass.
2.9.6
Select Damping of Rate of Turn
This operation is only possible if the distribution unit 138-118 is
connected. The damping of the RoT is not possible if the distribution
unit 138-126 is connected.
1.
Open the sub-menu Rate of Turn from the service page, see chapter 2.9.1.
- The sub-menu Individual Rate of Turn opens.
2.
Use the Select buttons (Figure 2-3/1 and 2) to navigate through the options.
3.
Use the Set button to select a damping mode.
2.9.7
Set Speed Error Correction
1.
Select the sub-menu Spd Err. Corr. from the service page, see chapter 2.9.1.
2.
Use the Set button (Figure 2-3/11) to open the sub-menu.
- The sub-menu Speed Error Correction opens.
- The option “Display Spd/Lat” is highlighted (Figure 2-14).
Figure 2-14
Display Spd/Lat