![Raytheon Anschütz Standard 22 GYRO COMPASS Operator'S And Service Manual Download Page 63](http://html1.mh-extra.com/html/raytheon-anschutz/standard-22-gyro-compass/standard-22-gyro-compass_operators-and-service-manual_3962997063.webp)
2-21
3.
Press the Set button (Figure 2-3/11) to select another speed source, if available.
4.
Select “Back” with the Select buttons (Figure 2-3/1 and 2) to leave the sub-menu.
5.
Press the Set button to confirm leaving.
2.9.5
Deviation Table
Set, edit or erase the correction value to correct the magnetic heading information.
Figure 2-13
Deviation Table
1.
Open the sub-menu Deviation Table from the service page, see chapter 2.9.1.
- The sub-menu deviation Table opens, see Figure 2-13.
2.
Use the Select buttons (Figure 2-3/1 and 2) to navigate through the options:
1.
Edit value and set value: A correction value can be edited and/or set.
2.
Erase value: Erases a selected value.
3.
Erase all values: Erases all correction values of the deviation table.
If this option is selected, the safety question “Are you sure” has to be confirmed
with the Set button.
4.
Back: Switches back to the previous page.
3.
Press the Set button (Figure 2-3/11) to confirm the selection.
4.
Use the Select buttons to navigate through the deviation table.
5.
Press the Set button to activate the respective field.
6.
Use the Select buttons to enter or edit a value.
7.
Press the Set button to confirm the change.
2.9.5.1
Deviation Tables in a GG-R System
If more than one magnetic compasses are connected in a GG-R system, the deviation
table must be edited for every magnetic compass.