2-13
The following table shows the possible settings for a heading difference.
Table 2-1
Heading Difference, Settings
Parameter
G/M
G/G
Threshold (min)
3,0°
3,0°
Threshold (max)
50,0°
30,0°
Increment
1/10°
1/10°
2.9
Service Page Settings
Following service page settings are possible:
•
Set Heading Difference
•
Set Switch-Over Auto Heading
•
DV-Bus Settings
•
Change Speed Source DU
•
Deviation Table
•
Select Damping
•
Set Speed Error Correction
2.9.1
Open the Service Mode
If nothing is changed and no sub-menu is selected, the service page
switches back to the overview page after approx. 10 sec.
1.
Press the Page button (Figure 2-3/3) and navigate to the heading difference / service
page.
2.
Use the Select buttons (Figure 2-3/1 and 2) to navigate to Exit.
- Exit is highlighted.
- Additional text “Press Down Button for approx. 3 s. to enter Service Mode” is
displayed on the screen (see Figure 2-8).