3-15
Pos. No. Designation
Function
6
Plug B5
Serial Input 1 (RS422)
and
Serial Output RS422
Depending on switches B14, B16 and B17 the
contacts for Serial Output are used for a RS485
interface (Data in and out).
For Bridge Alert Management (BAM): Set the gyro
Operator Unit to RS422.
7
LED H3
Flashes (green) if there is a data transmission via
RS422 Output (or RS485) at plug B5.
8
Switch B2
Is used to terminate Serial In at plug B5.
9
LED H4
Lights up (green) if “Relay Switching Output 1” is
active.
10
LED H10
Lights up (green) if “Relay Switching Output 3” is
active.
11
Plug B6
Relay Switching Output 1 and Relay Switching
Output 2
Out 1: Alert to BNWAS.
Out 2: Currently not used.
12
Plug B11
Relay Switching Output 3 and Relay Switching
Output 4.
Out 3, 4: Currently not used.
13
LED H5
Lights up (green) if “Relay Switching Output 2” is
active.
14
LED H11
Lights up (green) if “Relay Switching Output 4” is
active.
15
Plug B7
CAN1 (of the Dual-CAN-Bus)
16
LED H6
Flashes (green) if there is a data transmission via
plug B 7.
17
Plug B3
Development only.
18
LED H7
Flashes (green) if there is a data transmission via
plug B8.
19
Plug B8
CAN2 (of the Dual-CAN-Bus)
20
LED H22
Lights up (green) if 24.5V DC for display
background illumination is available.
21
LED H21
Lights up (green) if 14.6V DC for signal horn is
available.
22
LED H19
Lights up (green) if 5V DC for CAN2 is available.
23
LED H18
Lights up (green) if 5V DC for CAN1 is available.
24
LED H17
Lights up (green) if 5V DC for the internal
electronic is available.