Raytec Americas:
+1 613 270 9990 • [email protected]
Raytec Ltd reserve the right to change specifications without prior notification or public announcement.
Version 1
www.raytecled.com
1277-D
-0008
Installation Steps
Hook Pendant Installation (Ordered Separately)
Step 1.
Step 2.
Step 3.
Step 4.
Step 5.
Step 6.
This SPX-BKT-XR-HK kit is intended for use with UL Listed XR luminaire as marked on the luminaire nameplate.
Accessory Package Contents
Refer to alternate instructions if using Wall, Hook, Pole or Yoke Mount
Inspect shipping package and contents to ensure no damage has occurred during
shipping. Discard surface/ceiling mounting bracket provided with AR luminaire.
It is recommended to install Secondary Safety Cable by looping appropriate steel
cable or chain through the outer band of the unit and fastening a closed loop.
Secondary safety hardware must be rated for a minimum of 110lbs. Secondary safety
cables made from stainless steel aircraft cable are available upon request.
Slide anti-rotation lock onto suspension hook assembly and install hook
assembly into ¾ NPT threaded entry. Tighten to hand tight plus 1 to 2 turns.
Slide anti-rotation lock into place and tighten set screw to lock unit in place.
NOTE: To aid in assembly and provide protection against ingress, use of a
petrolatum or soap thickened mineral oil based thread lubricant/sealant is
necessary.
Un-used conduit opening must be plugged to maintain the integrity of the
enclosure.
Latch hook onto eye-bolt or other fixed mounting loop. Mounting point must be
rated for a minimum of 110lbs.
Install remaining loop of secondary safety chain or steel cable to suitable mounting
location and fasten securely.
Resume installation instructions provided with luminaire. (STEP 4 in XR Installation
Instructions from the Surface/Ceiling Mount installation provided with Luminaire).
SPX-BKT-XR-HK
QTY
PART NAME
1
PENDANT HOOK ASSEMBLY
1
ANTI-ROTATION ASSEMBLY
Step 2
Step 3
SPZ-XR