Raytec Americas:
+1 613 270 9990 • [email protected]
Raytec Ltd reserve the right to change specifications without prior notification or public announcement.
Version 1
www.raytecled.com
1277-D
-0008
XR Bay luminaires are designed for use indoors, outdoors, wet locations, areas containing moisture, dirt, corrosion,
vibration and rough usage. The XR Bay luminaire has been certified for use on marine vessels inside, outside, and
in other severely wet saltwater environments.
UL 844, UL 1598, UL 1598A, and UL 8750;
CSA C22.2 No. 137, CSA C22.2 No. 250.0 and CSA C22.2 No. 250.13
Hazardous Location Certication:
Class I, Division 2, Groups ABCD;
Class II, Division 2, Groups FG;
Class III;
Class I, Zone 2, Group IIC;
Zone 22
3 x 3/4” NPT Conduit | Black: Line | White: Neutral | Green: Ground
Optional: Violet: 0-10V Dimming (+) | Grey: 0-10V Dimming (-)
For connections use wire rated to a minimum of 90°C. Class 1 Wiring only.
Dimming control wires must be rated 300V minimum for luminaires with suffix AC,
600V minimum for luminaires with suffix HV.
Certified to:
Connections:
Housing:
Ingress Protection:
Ambient
Temperature
Range:
Input Voltage:
Electrical Ratings:
Copper-free Cast Aluminium with Polycarbonate lens
IP66/67 | Suitable For Wet Locations. Marine Outside Type (Salt Water)
Based on luminaire suffix in table below: Suffix - AC: 120-277 VAC | Suffix - HV: 347-480 VAC
Class I Division 2 | Class I Zone 2 Class II Division 2 | Zone 22
XR8: -50°C to +75°C T3C
All models -50°C to +50°C T3C
XR10: -50°C to +74°C T3C
XR15: -50°C to +74°C T3C
XR20: -50°C to +67°C T3
Application
Model
Input Voltage
Rated Wattage [Watts]
Rated Voltage
[Volts]
Freqeuncy
[Hz]
XR8
AC
Flood: 47 Optic: 60
120-277
50/60
HV
Flood: 49 Optic: 64
347-480
50/60
XR10
AC
Flood: 55 Optic: 75
120-277
50/60
HV
Flood: 58 Optic: 77
347-480
50/60
XR15
AC
Flood: 84 Optic: 103
120-277
50/60
HV
Flood: 91 Optic: 107
347-480
50/60
XR20
AC
Flood: 141 Optic: 156
120-277
50/60
HV
Flood: 148 Optic: 160
347-480
50/60
Surface/Ceiling Mounting Installation
SPZ-XR
E477827