There are many possible custom configuration scenarios. The following schematic diagram
illustrates the possible interconnections and the examples are intended as a guide only.
Example 1 : (Default Setting)
Switch 1
Switch 2
Switch 3
Switch 4
OFF
OFF
ON
OFF
Both Lamps enabled by either Aux Telemetry, Cam1 O/P or Cam2 O/P : Short Circuit=ON
Conditional on Photocell status
– Lamp ON in darkness (Unless Lamp Pcell is optionally disabled)
Cameras (or a PIR) can switch the lamp ON when motion is detected. Telemetry is a remote switch.
Example 2 : (Photocell Linking)
Switch 1
Switch 2
Switch 3
Switch 4
ON
OFF
ON
OFF
Common photocell status on Lamp1 and 2 (unless disabled) is reported to both camera inputs.
Allows camera day/night switching and synchronised ON/OFF switching as Example 1.
Example 3 : (Forced Telemetry)
Switch 1
Switch 2
Switch 3
Switch 4
ON
OFF
ON
ON
Common photocell status on Lamp1 and 2 (unless disabled) is reported to both camera inputs.
Camera Day/Night switching is maintained but both Lamps are forced ON in the dark state.
Camera output control and Aux Telemetry function are disabled.