Raytec APIs (VMS and HTTP)
The Raytec Network Illuminator has been designed such that it can be integrated into
3
rd
party systems such as a VMS, BMS etc. as well as receiving HTTP commands and
Raytec have suitable APIs to support such integrations. Please contact Raytec to
discuss your particular requirements.
For full documentation to support API implementation, please contact Raytec.
Troubleshooting & FAQs
Typical Questions:
Please see Basic Troubleshooting on pages 20-21
Also, please feel free to contact us directly on the contact numbers below.
I have forgotten my Password.
–
If you are an operator, contact your administrator. If
you are an administrator, then you may need to perform a hard reset of the
illuminator
–
see previous page.
I cannot discover my illuminator on the network using the Raytec Discovery Tool.
–
Check that there is power to the illuminator, check that the correct CAT 5 / 6 wiring is
being used, check that your computers Firewall is allowing the illuminator access and
is not blocking UDP traffic.
I cannot communicate with my illuminator from the Raytec Discovery Tool
–
Make
sure the IP address of the computer and the illuminator are set to the same range to
allow communication. The default IP address of the illuminator is 192.168.2.80.
My illuminator turns on too early or too late
–
First adjust the Photocell Sensitivity on
the
Adv. Settings
web page. Make sure the illuminator is not mounted under or next
to another another light source which may affect the performance of the photocell.
I want my illuminator to turn ON via the photocell
–
Photocell operation is activated
as a factory default setting and will turn the illuminator on/off automatically provided