41
User Interface
The user interface consists of several Menu options.
Press the
MENU
button to scroll through the different
menus in the interface. Press the
ITEM
button to scroll
through available items within a selected menu. And,
the
UP
and
DOWN
buttons allow for setting changes
to items in the
ADJUST
menu. Refer to Fig. 44 for dis-
play and key locations.
For detailed descriptions of the various screens, con-
sult the VERSA IC Control Applications Guide (Catalog
No. 5000.72).
Adjusting the XPak FT Setpoint
To adjust the setpoint on the XPak FT:
Use the
MENU
key to scroll to the
ADJUST
menu,
then use the
ITEM
key to scroll to the
SETPOINT
item.
Adjust the Setpoint using the
UP
and
DOWN
arrow
keys. Minimum is 50
°
F, Maximum is 192
°
F, and the
default is 180
°
F for H models.
Item
Application
Description
OUTDOOR
MODE 1, 2, 3
Outdoor air temperature, available when TARGET = RSET in ADJUST menu.
Target
MODE 1, 2, 3
Current target temperature, available when TARGET = SETP in ADJUST
menu (Defautl), (EMS /MODB)
SUPPLY
MODE 1, 2, 3
Current system supply temperature
IND SUPPLY
MODE 3
Current temperature being supplied to the indirect system
Boil OUTLET
All
Current boiler outlet temperature
Boil INLET
All
Current boiler inlet temperature
Boil ΔT
All
Current temperature difference between boiler outlet and boiler inlet
DHW SUPPLY
MODE 2, 3
Current indirect DHW supply temperature
BOILER STATUS
All
IDLE, PREP, IGN, MOD RATE %, POST, SOFT
View Menu
The
VIEW
menu is the default menu. See Table P. It
displays sensor temperatures, the modulation rate of
the blower, heater cascade status, pump operation
and CFH information. Some of the items displayed are
mode-specific and are only observable when its corre-
sponding mode is active.
Setup Menu
To change settings use the
MENU
key to scroll to the
ADJUST
menu. The
ADJUST
menu allows the
installer to make adjustments to items shown in
Table Q.
Refer to the VERSA IC Control Applications Guide
(Catalog #5000.72) for detailed setup instructions.
Table P: View Menu
Fig. 44: User Interface
Summary of Contents for 88AR-398A
Page 18: ...18 Fig 13 MODE 1 Single Boiler Primary Secondary Piping...
Page 19: ...19 Fig 14 MODE 2 Single Boiler Primary Secondary Piping with Indirect DHW on System Loop...
Page 20: ...20 Fig 15 MODE 3 Single Boiler Primary Secondary Piping with Indirect DHW on Boiler Loop...
Page 47: ...47 WIRING DIAGRAM Fig 46 Wiring Diagram...
Page 54: ...54 Fig 55 Boiler Lighting Shut Off Instructions...
Page 65: ...65 ILLUSTRATED PARTS LIST...
Page 66: ...66...
Page 67: ...67...