36
RC435 and RC435i Chartplotters
Units
This sets the units for distance, speed and depth. This setting will be used
to display all data. However, the distance units do not affect the chart
scale, which is always in nautical miles.
Variation
The variation value is the difference between True and Magnetic
direction data for heading or bearing values. The Magnetic value is
derived from True by applying the user selected value of variation.
The variation is set in 1° steps to 30° East or West. Press trackpad right to
move the value eastward, or left to move it westward. The selected value
is retained when the unit is switched off. The Default value is zero.
Note:
Variation can only be changed if the
VARIATION MODE
is set to
MANUAL
Variation Mode
This can be set to
AUTO
or
MANUAL
. In
AUTO
mode, the RC435/435i
automatically calculates and sets the magnetic variation. Set this to
MANUAL
to enter your own value.
Date Format
Set the preferred date format (
DD/MM/YY
or
MM/DD/YY
). The selected
setting is retained when the unit switched off. The Default is
DD/MM/YY
.
Time Offset
To display local time, use the trackpad to change from
UTC
(Universal
Time Constant, also known as GMT) to the desired time offset. This can
be up to ±13 hours, in 1 hour steps. The default is
UTC
.
Language
Select the language in which information is to be displayed. The selected
language is used for screen text, labels, menus and options. Chart text,
provided by the chart card, is not affected.