Sharing a breaker
Where more than 1 piece of equipment shares a
breaker you must provide protection for the individual
circuits. E.g. by connecting an in-line fuse for each
power circuit.
D11637-2
2
4
4
1
3
+
-
1
Positive (+) bar
2
Negative (-) bar
3
Circuit breaker
4
Fuse
Where possible, connect individual items of
equipment to individual circuit breakers. Where this
is not possible, use individual in-line fuses to provide
the necessary protection.
4.5 Connecting handsets and cables
Follow the steps below to connect handsets and
extension cables together.
1. Ensure the cable connectors are correctly
orientated.
2. Ensure connectors are fully inserted.
3. Tighten locking collars by Rotating clockwise.