Appendix ATechnical specification
GPM400 Processor module
GPM400 Processor module
Nominal supply
voltage
12 V / 24 VDC
Operating voltage
range
10.7 V to 32 V DC
Fuse / Breakers
12 V supply:
10 A fuse protection at distribution panel
10 A thermal circuit breaker protection at distribution
panel
24 V supply:
4 A fuse protection at distribution panel
5 A thermal circuit breaker protection at distribution
panel
Typical Power
consumption
No external loads
3 A @ 12 V
1.5 A @ 24 V
With external loads
5 A @ 12 V
2.5 A @ 24 V
Environmental
conditions:
operating temperature: -15°C to 55°C (5°F to 131°F)
non-operating temperature: -25°C to 70°C (-13°F to
158°F)
relative humidity limit: 80%
water protection: drip resistant when mounted
vertically
Storage conditions for
packaged unit:
Temperature: -25°C to 55°C (-13°F to 158°F)
relative humidity: 75%
Dimensions:
Width = 335 mm (13.19 in)
Height =230 mm (9.06 in)
Depth = 125 mm (4.92 in),
Weight
6.5 kg (14.33 lb)
Data connections
NMEA 0183 (x2)
SeaTalk
SeaTalk
ng
SeaTalk
hs
Compact flash
USB (software upgrade only)
Video
DVI x 2
(Optional VGA adaptor available)
Audio
Stereo line out (rated 1 V rms)
SeaTalk / alarm power
output
250 mA at 12 V
CE approvals -
conforms to:
89/336/EEC as amended by 92/31/EEC,
EN60945:2002
GPM400 Processor module
Summary of Contents for G-Series system
Page 1: ...G Series Systems Installation and Commissioning Instructions...
Page 2: ......
Page 3: ...G Series System Installation Commissioning Instructions Document Number 87070_1 Date June 2007...
Page 6: ...G Series Installation Commissioning 6...
Page 10: ...G Series Installation Commissioning 10...
Page 14: ...G Series Installation Commissioning 14...
Page 30: ...G Series Installation Commissioning 30...
Page 56: ...G Series Installation Commissioning 56...
Page 68: ...G Series Installation Commissioning 68...
Page 72: ...G Series Installation Commissioning 72...
Page 80: ...G Series Installation Commissioning 80...
Page 102: ...G Series Installation Commissioning 102...
Page 108: ...G Series Installation Commissioning 108...
Page 120: ...G Series Installation Commissioning 120...
Page 126: ...G Series Installation Commissioning 126...
Page 127: ......