55M4500CCE00 REV A
“Transfer” restoring calibration and load chart files
Warning:
This procedure will overwrite the existing data in the i4500 system and the
existing data will be lost. It is advisable to archive copies of the existing data using the
procedure in step #21 as a precaution before continuing. If in doubt consult Rayco
Wylie.
A copy of the calibration and/or load chart files can be restored to the i4500 system at
any time.
Note
a USB memory stick must be connected to connector ‘B’ of the i4500
display unit using a Deutsch to USB converter lead (RaycoWylie part no. 33V0414)
before proceeding. Ensure the file required to be restored is saved in the root folder of
the USB stick.
Navigate through the calibration menu using
“
”
or
“
”
to highlight “transfer” and
press
“
”
to enter.
Select “transfer from USB to system” ” and press
“
”
To restore a load chart file select “usb stick ‐> Load chart” ” and press
“
”
or to restore
a calibration file select “usb stick ‐> Calibration” ” and press
“
”
,