55M4500CCE00 REV A
Use
“
”
or
“
”
to set
xx
to the required number of angle steps for calibration length 1
then press
“save”
to accept.
Enter the number of angle calibration points for each length step in turn as prompted.
Setting the maximum boom angle:
The display will show:
Derrick the boom up to the maximum possible angle, that is, with the boom hoist
cylinder
almost
fully extended, just avoiding the maximum boom angle stops and press
“
”
when done.
Setting the minimum boom angle for each calibration length:
The display will show:
Minimum angle for length 1 =
xx.xx
Where
xx.xx
is the lowest working angle in degrees for length 1. Check the load chart
and determine the lowest rated angle for each of the boom lengths you have previously
entered; i.e. length 1, length 2, etc. and enter separate minimum working angles for
each calibration length as prompted. When complete the display will show: