55M4500CCE00 REV A
External setup button.
Optional feature, if enabled then setting this to ON will allow
the setup bypass feature to be available via an external digital input.
Return time from limits.
Not enabled unless the range limiting feature is fitted. This
value represents the time allowed between setting a range limit and the limit becoming
active to allow the machine to be moved back into the permitted working zone.
Dyno version.
Must be set to
OFF
for this pressure sensing version of the i4500.
Step #8: “crane type”
This item is an option depending on the version of the software installed. When
available it allows the selection of one or more crane models within a single
manufacturer’s range to allow for differences in required features. It must be set to
precisely match the crane model to which the i4500 system is fitted.
Step #9: “bridging/bypass output”
This item is an option depending on the version of the software installed. When
available it allows the parameters to be set for the PWM output used to reduce the
machine speed during bridging or bypass functions.
Step #10: “picture”
This setting allows the graphic of the crane shown in the normal working window to be
set to a version that looks similar to the machine to which the system is fitted. It can be
set to any of the available choices at any time without changing the performance of the
system.