55M4500CCE00 REV A
Step #2: “Enable/Disable i/o” Setting
Note: these settings reflect the configuration of your system and will generally be
made during factory testing prior to delivery and should not need changing.
1‐ In the calibration menu, scroll up or down to the menu "Enable/Disable i/o".
2‐ Press
“
”
to enter this menu.
3‐ Scroll to select the I/O option to edit.
4‐ Press
“
”
to highlight the value to edit. Scroll up or down to change to value
then Press
“
”
to confirm.
5‐ Any change made must be permanently registered by pressing the
“save”
button.
6‐ Press
“
”
at any time to abandon any changes not saved or to exit the menu
when done.
As a guide, the minimum requirements for a basic system are:
Angle 1
ON
Length 1
ON
Load 1
ON
Load 2
ON
Relay board 1 ON
All remaining items in the list are optional and set to OFF if not used.
Refer to the wiring diagram supplied with your system to determine which I/O should be
enabled, this will be indicated by a table or a notation adjacent to each component. See
example below: (Ref Load 1 and Load 2) means that these two I/O items need to be ON.