P/N 016-0171-277 Rev. L
17
CR7 CALIBRATION AND OPERATION
4. Proceed to “Engage Switch and Node Orientation” on page 17 to continue with the SmarTrax system
calibration.
SMARTRAX SYSTEMS WITH A PRESSURE TRANSDUCER INSTALLED
NOTE:
This section applies only to SmarTrax systems utilizing pressure transducers to disengage the
SmarTrax system when the steering wheel is turned. If a pressure or flow switch is installed in the
SmarTrax system, refer to “SmarTrax Systems with a Pressure Switch or Flow Switch Installed” on
page 16 to calibrate the SmarTrax system.
FIGURE 8. Transducer Calibration Screens
1. When prompted, turn the steering wheel 90° to allow the SmarTrax system to detect the hydraulic pressure
change. Once the system has detected the static and differential pressures, a screen displaying the steering
wheel status will appear.
NOTE:
“Steering wheel is stationary” is displayed until the wheel is manually turned, at which point the
“Steering wheel is moving” will be displayed.
2. Verify that the CR7 displays the correct steering operation.
NOTE:
It may be necessary to increase the disengage setting to require more steering input to disengage
SmarTrax or to decrease the disengage setting to require less steering input.
3. If the system setting is correct, select
Next
to proceed to the next step in the calibration procedure.
ENGAGE SWITCH AND NODE ORIENTATION
FIGURE 9. Engage Switch Calibration Screen
1. Review the on-screen instructions.
Summary of Contents for SmarTrax
Page 12: ...CHAPTER 1 6 SmarTrax Calibration Operation Manual ...
Page 16: ...CHAPTER 2 10 SmarTrax Calibration Operation Manual ...
Page 42: ...CHAPTER 3 36 SmarTrax Calibration Operation Manual ...
Page 76: ...CHAPTER 4 70 SmarTrax Calibration Operation Manual ...
Page 138: ...CHAPTER 6 132 SmarTrax Calibration Operation Manual ...
Page 151: ...8 P N 016 0171 277 Rev L 145 SYSTEM DIAGRAMS FIGURE 4 SmarTrax with Envizio Pro and RGL 600 ...