SmarTrax™ Calibration & Operation Manual
SMARTRAX OPERATION
Vlve Flt
Communication could not be established
with the Steering Ready ISO valve.
Verify the proper software version is
installed on the machine’s ISO CANbus.
Verify that the system is connected to a
Raven-supported, ISO-compatible valve.
Wrong HDW
The software and hardware versions of
the node are not compatible.
Update the node software to the proper
version.
XDucer Er
A problem with the pressure transducer
or cabling has been detected.
Verify the PSI values on the System
Diagnostics screen.
Verify pressure transducer connection
and cabling.
Replace the transducer(s).
Yaw Error
Yaw rate sensor values are out of range.
Replace the SmarTrax node.
Problem
Possible Cause
Corrective Action
SmarTrax will not power up.
The power connections are loose
or not properly connected.
Check the power connections to
ensure they are secure and
properly connected.
The fuse is blown.
Replace the fuse.
The battery connections are loose,
corroded, or not properly
connected.
Check the battery connections to
ensure they are secure and
properly connected.
The machine does not have proper
voltage to run the system.
Test for +12VDC using a voltmeter.
The field computer or cabling is
defective.
• Test the cable voltage from the
field computer to the node.
• Replace the field computer.
Message
Possible Cause
Corrective Action
Summary of Contents for SmarTrax
Page 12: ...CHAPTER 1 6 SmarTrax Calibration Operation Manual ...
Page 16: ...CHAPTER 2 10 SmarTrax Calibration Operation Manual ...
Page 42: ...CHAPTER 3 36 SmarTrax Calibration Operation Manual ...
Page 76: ...CHAPTER 4 70 SmarTrax Calibration Operation Manual ...
Page 138: ...CHAPTER 6 132 SmarTrax Calibration Operation Manual ...
Page 151: ...8 P N 016 0171 277 Rev L 145 SYSTEM DIAGRAMS FIGURE 4 SmarTrax with Envizio Pro and RGL 600 ...