CHAPTER 9
74
Raven SC1™/TC1™ (software version 1.5) Calibration & Operation Manual for Tractors and Sprayers
RADIO MODE CONFIGURATION
1. Press the Right button until “Configuration” displays on the screen.
2. Press the Down button to select “Configuration”.
3. Press the Right button until “RTK Config” displays.
4. Press the Down button to select “RTK Config” displays.
5. Press the Down button until “Delivery” displays.
6. Select the Right button to set “Delivery” to Trimble CMRRadio.
FIGURE 3. Delivery Setting
7. Select Enter to save the settings.
PORT A CONFIGURATION
1. Press the Right button until “Configuration” displays on the screen.
2. Press the Down button to select “Configuration”.
3. Press the Right button until “Port A Config” displays.
4. Press the Down button to select “Port A Config”.
5. Ensure the Input (I) messages are set to None and the baud rate is set to 115K.
6. Verify the Output (O) messages are set to 8N1 and that the NEMA and baud rates are set to 115K.
FIGURE 4. Port A Configuration
7. Press Enter to save the settings.
8. Press the Down button until “NEMA1” displays.
9. Verify GGA and GSA are capitalized so they are on.