2.2. Checking the hydraulic manifold
The hydraulic implement manifold is suited for
use in both Load-Sense (L.S.) and Open Center
(O.C.) hydraulic systems. Depending on the
type of installation a different type of selector
plug must be installed in the manifold (Table 1,
Figure 2).
Check the type of the selector plug (Figure 1)
before mounting the manifold.
If the manifold is connected to the auxiliary
hydraulic connectors at the rear of the tractor,
the manifold must be configured in Open
Center mode. The LS connector must be
capped.
When Open Center is chosen, other
selector plugs need to be used in the
manifold than when Load Sense is used!
2.3. Mounting the hydraulic manifold
For mounting purposes the manifold is
equipped with 3x M8 holes with internal thread.
Attach the manifold to the supplied manifold
bracket (Figure 3).
Place the manifold in such a way that the
hydraulic hoses from the manifold can be
easily directed towards the tractor and the
control cylinder. Ensure that the DIN
connectors on the valve can be connected after
fitting the manifold. Connect the control
cylinder to A and B of the manifold.
Type of hydraulics Selector plug
Load Sense
SBG10810
Blind plug without imprint
Open Center
SBG10820
ELP30/D2
Table 1 Selector plug manifold
Figure 1 Selector plug
Figure 2 Selector plug. Left: L.S. Right O.C.
Figure 3 Manifold and STU mounted on Side-Shift
frame