141
ENGLISH
7 CONNECTIONS
The connections must be set up by a technician
that is qualified and/or authorised by the
Manufacturer.
By the installer the type of cable, with relative
section, to be installed in case of replacement
is: H05RR-F sez.3G0,75
7.1 CONNECTION WITH EXTERNAL AIR
INTAKE
To make the connection with an external air
intake, proceed as follows:
STEP
ACTION
1
Connect a 50 mm diameter pipe to
the combustion air inlet pipe at the
back of the stove. Note: the pipe must
be no more than 2 m in length.
The air vent must be installed in such a way that
it can not be blocked.
7.2 CHIMNEY CONNECTION
The chimney must be sized so as to guarantee
the draught declared by the Manufacturer.
The stove must be connected to a single flue. It
is forbidden to connect the stove to a flue shared
with other combustion appliances or with hood
exhausts.
The flue must be inspectable for cleaning.
7.3 STANDARD INSTALLATION
The tubes shown are not supplied with the unit.
Fig. 7.1
Break the
pre-cut only
if you want
to connect
to an
external air
intake
7.4 ELECTRICAL CONNECTION
The plug of the stove’s power cable must
only be connected after the installation
and assembly has been completed
of the appliance, and must remain
accessible after installation.
To make the electrical connection, proceed as
described below:
• First connect the power cable to the plug on
the back of the stove and then to a wall socket.
• Supply power to the stove by turning the switch
to position (I).
When the stove is not in use, it is advisable to
disconnect the power cable.
Take care that the power cord (and any other
cables outside the equipment) do not come into
contact with hot surfaces.
Ensure that the electrical system is grounded.
For direct connection to the mains, it is necessary
to provide a device that ensures disconnection
from the mains, with a contact opening distance
that allows complete disconnection under
the conditions of overvoltage category III, in
accordance with installation rules.
If the power supply cable is damaged, it must
be replaced by the manufacturer or its technical
assistance service or in any case by a person with
similar qualifications, so as to prevent any risk.
It is recommended that authorized personnel pay
special attention to the electrical connections
after any work on the product.
7.5 TESTING AND COMMISSIONING
Stove start-up must be preceded by testing,
which includes an operational check of the
following elements:
• connection to the smoke evacuation system;
• electrical connections;
• operation of any connected external probes;
• checking that all materials used to build the
smoke duct, chimney and chimney pot are
regulation and suitable for use.
The testing is positive only when all operational
phases have been completed without any
anomaly being detected.
Switch
Power plug
Fuse
Fig. 7.2
Summary of Contents for BLOCK 7 STONE
Page 26: ...26 ITALIANO Fig 8 28 Fig 8 29 Fig 8 30 Fig 8 31...
Page 88: ...88 FRANCAIS Fig 8 28 Fig 8 29 Fig 8 30 Fig 8 31...
Page 149: ...149 ENGLISH Fig 8 28 Fig 8 29 Fig 8 30 Fig 8 31...
Page 187: ...187 ENGLISH...
Page 190: ......
Page 191: ......