Maintenance and repair
C
188
AXIS
AXIS
50.2
Adjusting AXIS 50.2 D:
The metering slide is in the position of step 2 (lightly pressed against the pin).
3.
Loosen the fixing screws on the scale of the lower scale arc.
Figure 24:
Adjustment scale of metering slide
4.
Adjust the scale in such a way that the
scale value 85
lies exactly under the
pointer element. Screw the scale back on.
5.
Repeat working steps 1 - 2 and 7 - 8 for the right metering slide.
6.
Reattach the return spring and the hydraulic cylinders.
NOTICE
Both metering slides must open
evenly
and to the same extent. Therefore, al-
ways check both metering slides.
NOTICE
After scale correction with electronic slide actuators, a correction of the slide
testing points in the operating unit is necessary.
Please observe the operator’s manual for the operating unit.