Spreading operation
B
142
AXIS
AXIS
30.1, AXIS 40.1
Calculation with formula
The position of the output rate stop can also be calculated using the following for-
mula:
13.
End calibration test. Switch off the PTO shaft and tractor engine and lock
them to prevent unauthorised starting.
14.
Mount the spreading discs. Make sure that the left and right spreading discs
are not reversed.
NOTICE
You can use the percentage scale to reset the position of the output rate stop.
For example, if the calibration test weight is down by 10 %, the output rate stop
is set to a 10 % higher position (e.g. from 150 to 165).
New position
of the output-
rate stop
=
Position of the output rate stop during
current calibration test
x
Nominal out-
put quantity
Actual output quantity during the current calibration test
NOTICE
The pins on the spreading disc holders have different positions on the left and
right side. The correct spreading disc is the one that fits precisely into the
spreading disc holder.
15.
Carefully position the cap
nut (do not tilt).
16.
Tighten the cap nut with ap-
prox.
38 Nm
. Do
not
use the
adjustment lever.
Figure 13:
Screw on the cap nut
K
D
R
C
Q
W
EMC
Summary of Contents for AXIS-M 20.2 EMC
Page 4: ......
Page 12: ...Table of Contents VIII ...
Page 44: ...Safety 3 24 AXIS AXIS ...
Page 51: ...Technical data 31 4 AXIS AXIS 4 2 4 Agitator Figure 4 6 Agitator 1 Metering slide 2 Agitator ...
Page 64: ...Axle load calculation 5 44 AXIS AXIS ...
Page 66: ...Transportation without tractor 6 46 AXIS AXIS ...
Page 68: ...Instructions regarding the spreading operation 7 48 AXIS AXIS ...
Page 110: ...General commissioning all machine types 8 90 AXIS AXIS ...
Page 144: ...Maintenance and repair C 124 AXIS AXIS 20 2 ...
Page 178: ...Maintenance and repair C 158 AXIS AXIS 30 1 AXIS 40 1 ...
Page 214: ...Maintenance and repair C 194 AXIS AXIS 50 2 ...
Page 236: ......