The manual mode is only applied:
•
If there is no speed signal (radar or wheel sensor not available or defective)
•
when spreading slug pellets or fine seeds
The MAN scale operating mode is appropriate for slug pellets and fine seeds since the automatic
mass flow control cannot be activated due to the low weight reduction.
For uniform spreading of the spreading material, a constant forward speed must be applied in
manual operating mode.
Fig. 48: MAN scale operating screen
[1]
Display of metering slide target value scale
position
[2]
Display of current metering slide scale
position
[3]
Application rate adjustment
u
Access the menu Machine settings > AUTO/MAN mode.
u
Select the MAN scale menu item.
The Position of dosing slider opening window is displayed.
u
Enter the scale value for the dosing slider opening.
u
Press OK.
u
Switch to the working screen.
5. Spreading operation with AXIS-PowerPack