8 P
ARAGON
II
/
C
OMMAND
C
ENTER
I
NTEGRATION
S
OLUTIONS
D
EPLOYMENT
G
UIDE
Updating UST-IP and IP-Reach Devices
CommandCenter Secure Gateway can also update any UST-IP or IP-Reach devices in your PCCI
configuration. Note that as part of a PCCI setup, the associated P2SC is still selected from the
Device tree, not the UST-IP or IP-Reach devices themselves.
Exception: If CommandCenter Secure Gateway directly manages the IP-Reach devices, you can
select the IP-Reach devices themselves from the Device tree.
1.
Click on the
Devices
tab and select the associated P2SC device from the Devices tree.
2.
On the
Devices
menu, click
Device Manager
, and then click
Remote User Station Admin
.
3.
CC-SG will display a list of IP-Reach and UST-IP units managed by P2SC. Make sure that
all IP-Reach and UST-IP units are listed before proceeding. If any are missing, wait a short
while then check again.
4.
On the
Devices
menu, click
Device Manager
, and then click
Upgrade Device
.
The
Upgrade
Device
screen appears.
5.
Click on the
Firmware Name
drop-down arrow and select the appropriate firmware from the
list for your UST-IP or IP-Reach.
6.
Click
OK
to upgrade the device or
Cancel
to close the
Upgrade Device
screen.
7.
If the firmware version of the device is not compatible with CC-SG, a message will alert you
and ask if you want to proceed. Click
Yes
to upgrade the device, or
No
to cancel the
operation.
8.
A
Restart
message appears; click
Yes
to restart the device or
No
to close the window without
restarting.
9.
A
Device Upgraded Successfully
message confirms that all devices of that type have been
upgraded.
Note: The P2SC device will reboot along with the UST-IP or IP-Reach devices once the firmware
upgrade is complete. Again, the P2SC will take several minutes to rediscover and catalog
assigned Paragon II configurations. Larger configurations will take longer rediscover, please
wait several minutes before trying to access the P2SC again.
This will upgrade all UST-IP or IP-Reach devices (depending on which firmware) at once. If you
use a mixture of UST-IP or IP-Reach units, repeat steps 1 through 6 to upgrade the other set of
devices.
Summary of Contents for Paragon II
Page 4: ......
Page 8: ......
Page 12: ...4 PARAGON II COMMANDCENTER INTEGRATION SOLUTIONS DEPLOYMENT GUIDE...
Page 22: ......
Page 32: ......
Page 36: ...28 PARAGON II COMMANDCENTER INTEGRATION SOLUTIONS DEPLOYMENT GUIDE...
Page 40: ......
Page 50: ...42 PARAGON II COMMANDCENTER INTEGRATION SOLUTIONS DEPLOYMENT GUIDE...
Page 53: ...APPENDIX A P2SC COMPATIBILITY LIST 45...
Page 60: ......
Page 63: ......