229
Machine No. from 10005200
EN
7
Maintenance
• After cleaning, all parts must be lubricated according to the maintenance schedule.
• Check nuts and screws are secure according to the maintenance schedule.
• When topping up with hydraulic oil, maximum cleanliness is required.
• Check hydraulic hoses and tubes acc. to the maintenance schedule for cracks and
damage, replace if necessary.
• The electrical system must be checked for damage and functionality according to the
maintenance schedule.
• Always make sure that the battery is well charged, if necessary charge the batteries with
the battery charger. Charging 12 V 0.6 A with an automatic mains charger.
If the machine is not used for more than 2 months:
• We would recommend closing the fuel valve while the engine is running and waiting until
the engine stops. It is essential that no fuel remains in the carburettor for long periods of
time.
• Using the specified personal protective equipment, the battery should be correctly remo-
ved, charged and stored in a cool, dry place.
• Battery maintenance includes monitoring and if necessary optimising the liquid levels
and charge state. To charge the battery, take the required precautionary measures and if
being put into storage for long periods, maintain an open-circuit voltage of 12.5 V.
Note
It is assumed that you have read and understood the chapters "First things first" and "Safe
operation".
Caution
The machine may suddenly trap the operator or third persons, cause them to fall over or
run them over.
• Cleaning and maintenance work and the removal of safety equipment should only be
carried out when the engine is turned off and the immobilisation brake applied.
Disconnect the spark plug terminal.
• Before undertaking any kind of work on the machine, let the machine cool down to a tem-
perature below 50 °C.
• Replace defective parts.
• The hydraulic system may be pressurised.
• When searching for leakages, suitable protection must be used (protective goggles and
protective gloves).
• The machine must be cleaned thoroughly before any work is undertaken on the
hydraulic system. Maximum cleanliness is required.