INSTALLING THE CHIMNEY HOOD

CLEARANCE HEIGHTS

The  chimney  hood  is  designed  to  be  fitted
over a cooking appliance. A minimum clear-
ance  height  of  650mm  (25˚ins)  is  required
when installed above a built-in electric hob,
or  700mm  (27˚ins)  when  installed  above  a
built-in gas hob.

When installed between adjoining wall cabi-
nets, the wall cabinets must not overhang the
hob and the distance between the underside
of the cabinet and worktop must be 450mm
(17˚ins), and a gap of 50mm (2ins) must be

maintained either side of the hob.

This chimney hood must not be in-

stalled above a cooking appliance with a

high level grill.

FITTING THE WALL BRACKETS

1.

Draw  a  vertical  line  on  the  wall  as
illustrated,  from  the  centre  of  the
cooking  appliance  up  to  the  ceiling
using  a  spirit  level  and  marker  pen.
This is to ensure the correct vertical
alignment of the various components
during installation.

2.

Place one of the brackets 

(2) 

against

the wall, centrally over the vertical line
approximately  2mm  from  the  ceiling
or  from  the  upper  most  fixing  point.

Align the bracket using a

 

spirit level

and  mark  the  two  keyhole  centre
positions for the upper bracket fixing
screws on the wall.

3.

Place the second bracket 

(2)

 against

the wall, centrally over the vertical line
at distance 

X

. (

X

 being determined by

the  measurement  of  the  upper
chimney). Align  the  bracket  using  a
spirit level and mark the two keyhole
centre positions for the middle bracket
fixing screws on the wall.

11

Summary of Contents for LEIHDS120SC

Page 1: ...LEIHDS120SC Users Guide Installation Instructions...

Page 2: ...Filters 6 Charcoal Filter 6 Lighting 7 Cleaning 7 INSTALLATION INSTRUCTIONS Technical Information 8 ELECTRICAL CONNECTION Elecrical Requirements 9 Electrical Connection 9 INSTALLING THE CHIMNEY HOOD...

Page 3: ...Height or if the motor becomes overheated If the cut out device is activated switch off the fan motor and allow the cooker hood to cool The cut out device will reset itself when the fan motor has coo...

Page 4: ...recommended Always insist on genuine RANGEmaster spare parts Under no circumstances should you attempt to repair the appliance yourself Repairs carried out by inexperienced persons may cause injury o...

Page 5: ...the canopy BUTTON L Turns the worktop lighting On and Off YOUR APPLIANCE BUTTON V1 Turns the fan On and Off at the low speed setting This is an ideal speed when cooking for long periods as the continu...

Page 6: ...les in either side of the chimney stack into the kitchen EXTRACTION In the extraction mode contaminated air enters the chimney hood through the grease filter cassettes and is passed out through ductin...

Page 7: ...a dishwasher or by hand using a mild detergent or liquid soap CHARCOAL FILTER In the recirculation mode the activated charcoal filter absorbs smells and unwanted odours The charcoal filter cannot be c...

Page 8: ...ps are specified 230V 20W When replacing the spotlamps make sure that the two pins are correctly inserted in the lamp holder and then replace the glass lens and retaining ring CLEANING We recommend th...

Page 9: ...ONSUMPTION 200W FAN 140W SPOTLAMPS 3x20W 60W PERFORMANCE SPEEDS 3 CAPACITY m3 h 550 CAPACIITY m3 h 690 PRESSURE PA 340 INPUT W 200 NOISE LEVEL dBA 67 IEC 61591 method for cooker hoods in evacuation mo...

Page 10: ...voltage corresponds to the voltage on the rating plate inside the cooker hood This appliance is fitted with a 3 core mains cable and must be permanently connected to the electricity supply via a doubl...

Page 11: ...nts for the discharge of exhaust air Incorrect installation may affect the safety of this chimney hood INSTALLATION REQUIREMENTS Before installation check the wall to which the hood is to be fitted fo...

Page 12: ...ALL BRACKETS 1 Draw a vertical line on the wall as illustrated from the centre of the cooking appliance up to the ceiling using a spirit level and marker pen This is to ensure the correct vertical ali...

Page 13: ...the wall Note If the chimney hood is to be installed onto a hollow construction plaster or partition board wall then special fixing screws will be required not supplied FIXING THE CANOPY 1 Before star...

Page 14: ...performance while reducing noise levels The ducting flange B should be sleeved over the spigot A when using 125mm 5ins ducting as the European ducting spigot is 120mm Ducting kits can be obtained from...

Page 15: ...chimney to the two brackets 2 using four of the screws provided with the fixing kit 2 To fit the lower chimney section I first apply pressure to expand the two side panels slightly to allow the chimn...

Page 16: ...4329643 03 020412...

Reviews: