COMPONENTS

The chimney hood comprises of the
following: -
No 1

150x120mm ducting spigot 

(A)

No 1

120x125mm ducting flange 

(B)

No 1

Canopy 

(C)

No 2

Recirculation grilles 

(G)

No 1

Lower chimney stack 

(I)

No 1

Recirculation ducting

 (P)

No 2

Recirculation extension ducts 

(P1)

No 1

Recirculation spigot 

(R)

No 1

Upper chimney stack 

(S)

No 1

Valve 

(V)

 optional

No 2

Chimney fixing brackets 

(2)

Please ensure when the appliance is fitted
it is easily accessible to an engineer in the

event of a breakdown.

All installations must comply with
local  authorities  requirements  for
the discharge of exhaust air.

Incorrect installation may affect the

safety of this chimney hood.

INSTALLATION REQUIREMENTS

Before  installation  check  the  wall
to which the hood is to be fitted for
electric  cables,  gas  and  water

pipes.

This chimney hood is designed to be fixed to
any vertical surface over a cooking area, and
can be used in the extraction (ducted to the
outside) or recirculation mode.

The installation work must be undertaken by
a qualified and competent person.

Leisure  Consumer  Products  disclaims  any
responsibility  for  damage  due  to  incorrect
installation of the chimney hood or if the hood
is  not  installed  in  compliance  with  relevant

regulations controlling this type of installation.

INSTALLING THE CHIMNEY HOOD

10

Summary of Contents for LEIHDS120SC

Page 1: ...LEIHDS120SC Users Guide Installation Instructions...

Page 2: ...Filters 6 Charcoal Filter 6 Lighting 7 Cleaning 7 INSTALLATION INSTRUCTIONS Technical Information 8 ELECTRICAL CONNECTION Elecrical Requirements 9 Electrical Connection 9 INSTALLING THE CHIMNEY HOOD...

Page 3: ...Height or if the motor becomes overheated If the cut out device is activated switch off the fan motor and allow the cooker hood to cool The cut out device will reset itself when the fan motor has coo...

Page 4: ...recommended Always insist on genuine RANGEmaster spare parts Under no circumstances should you attempt to repair the appliance yourself Repairs carried out by inexperienced persons may cause injury o...

Page 5: ...the canopy BUTTON L Turns the worktop lighting On and Off YOUR APPLIANCE BUTTON V1 Turns the fan On and Off at the low speed setting This is an ideal speed when cooking for long periods as the continu...

Page 6: ...les in either side of the chimney stack into the kitchen EXTRACTION In the extraction mode contaminated air enters the chimney hood through the grease filter cassettes and is passed out through ductin...

Page 7: ...a dishwasher or by hand using a mild detergent or liquid soap CHARCOAL FILTER In the recirculation mode the activated charcoal filter absorbs smells and unwanted odours The charcoal filter cannot be c...

Page 8: ...ps are specified 230V 20W When replacing the spotlamps make sure that the two pins are correctly inserted in the lamp holder and then replace the glass lens and retaining ring CLEANING We recommend th...

Page 9: ...ONSUMPTION 200W FAN 140W SPOTLAMPS 3x20W 60W PERFORMANCE SPEEDS 3 CAPACITY m3 h 550 CAPACIITY m3 h 690 PRESSURE PA 340 INPUT W 200 NOISE LEVEL dBA 67 IEC 61591 method for cooker hoods in evacuation mo...

Page 10: ...voltage corresponds to the voltage on the rating plate inside the cooker hood This appliance is fitted with a 3 core mains cable and must be permanently connected to the electricity supply via a doubl...

Page 11: ...nts for the discharge of exhaust air Incorrect installation may affect the safety of this chimney hood INSTALLATION REQUIREMENTS Before installation check the wall to which the hood is to be fitted fo...

Page 12: ...ALL BRACKETS 1 Draw a vertical line on the wall as illustrated from the centre of the cooking appliance up to the ceiling using a spirit level and marker pen This is to ensure the correct vertical ali...

Page 13: ...the wall Note If the chimney hood is to be installed onto a hollow construction plaster or partition board wall then special fixing screws will be required not supplied FIXING THE CANOPY 1 Before star...

Page 14: ...performance while reducing noise levels The ducting flange B should be sleeved over the spigot A when using 125mm 5ins ducting as the European ducting spigot is 120mm Ducting kits can be obtained from...

Page 15: ...chimney to the two brackets 2 using four of the screws provided with the fixing kit 2 To fit the lower chimney section I first apply pressure to expand the two side panels slightly to allow the chimn...

Page 16: ...4329643 03 020412...

Reviews: