background image

INSTALLING THE CHIMNEY HOOD

DUCTING

The hood is more effective when used in the
extraction mode (ducted to the outside).

When used in the extraction mode ensure the
ducting  spigot  has  been  correctly  fitted  as

illustrated.

The  ducting  used  must  be 

Æ

Æ

Æ

Æ

Æ

125

(5ins) or 

Æ

Æ

Æ

Æ

Æ

150mm (6ins), flexible or

rigid  and  must  be  manufactured
from  fire  retardant  material,
produced  to  BS.476  or  DIN.4102-
B1. The choice should be made by
the  installer.  However,  we
recommend flexible ducting should
only  be  used  as  an  accessory  as
rigid  ducting  will  provide  better
performance while reducing noise
levels.

The ducting flange 

B

 should be sleeved over

the  spigot 

A

  when  using  125mm  (5ins)

ducting  as  the  European  ducting  spigot  is

Æ

120mm.

Ducting  kits  can  be  obtained  from  Kitchen
Specialist Distriutors, Builders Merchants and
DIY stores.

When  the  chimney  hood  is  ducted  to  the

outside the charcoal filter must be removed.

RECIRCULATION

If you are using the hood in the recirculation

mode, ensure the charcoal filter is in position.

FITTING  THE  RECIRCULATION
DUCTING

1.

Connect the duct 

P

 to the round outlet

on top of the fan housing, which push
fits  into  position,  by  pressing  it
downwards  until  it  meets  the  fan
casing.

2.

Connect the spigot 

R

 on to the top of

the duct 

P

, which push fit into position,

13

Summary of Contents for LEIHDS120SC

Page 1: ...LEIHDS120SC Users Guide Installation Instructions...

Page 2: ...Filters 6 Charcoal Filter 6 Lighting 7 Cleaning 7 INSTALLATION INSTRUCTIONS Technical Information 8 ELECTRICAL CONNECTION Elecrical Requirements 9 Electrical Connection 9 INSTALLING THE CHIMNEY HOOD...

Page 3: ...Height or if the motor becomes overheated If the cut out device is activated switch off the fan motor and allow the cooker hood to cool The cut out device will reset itself when the fan motor has coo...

Page 4: ...recommended Always insist on genuine RANGEmaster spare parts Under no circumstances should you attempt to repair the appliance yourself Repairs carried out by inexperienced persons may cause injury o...

Page 5: ...the canopy BUTTON L Turns the worktop lighting On and Off YOUR APPLIANCE BUTTON V1 Turns the fan On and Off at the low speed setting This is an ideal speed when cooking for long periods as the continu...

Page 6: ...les in either side of the chimney stack into the kitchen EXTRACTION In the extraction mode contaminated air enters the chimney hood through the grease filter cassettes and is passed out through ductin...

Page 7: ...a dishwasher or by hand using a mild detergent or liquid soap CHARCOAL FILTER In the recirculation mode the activated charcoal filter absorbs smells and unwanted odours The charcoal filter cannot be c...

Page 8: ...ps are specified 230V 20W When replacing the spotlamps make sure that the two pins are correctly inserted in the lamp holder and then replace the glass lens and retaining ring CLEANING We recommend th...

Page 9: ...ONSUMPTION 200W FAN 140W SPOTLAMPS 3x20W 60W PERFORMANCE SPEEDS 3 CAPACITY m3 h 550 CAPACIITY m3 h 690 PRESSURE PA 340 INPUT W 200 NOISE LEVEL dBA 67 IEC 61591 method for cooker hoods in evacuation mo...

Page 10: ...voltage corresponds to the voltage on the rating plate inside the cooker hood This appliance is fitted with a 3 core mains cable and must be permanently connected to the electricity supply via a doubl...

Page 11: ...nts for the discharge of exhaust air Incorrect installation may affect the safety of this chimney hood INSTALLATION REQUIREMENTS Before installation check the wall to which the hood is to be fitted fo...

Page 12: ...ALL BRACKETS 1 Draw a vertical line on the wall as illustrated from the centre of the cooking appliance up to the ceiling using a spirit level and marker pen This is to ensure the correct vertical ali...

Page 13: ...the wall Note If the chimney hood is to be installed onto a hollow construction plaster or partition board wall then special fixing screws will be required not supplied FIXING THE CANOPY 1 Before star...

Page 14: ...performance while reducing noise levels The ducting flange B should be sleeved over the spigot A when using 125mm 5ins ducting as the European ducting spigot is 120mm Ducting kits can be obtained from...

Page 15: ...chimney to the two brackets 2 using four of the screws provided with the fixing kit 2 To fit the lower chimney section I first apply pressure to expand the two side panels slightly to allow the chimn...

Page 16: ...4329643 03 020412...

Reviews: