Regular maintenance and cleaning will ensure good performance and reliability, while
extending the working life of the hood. Special attention should be paid to the grease

filter cassettes and the charcoal filter when the hood is used in the recirculation mode.

Before  carrying  out  any  mainte-

nance or cleaning isolate the cooker hood

from the mains supply.

METAL GREASE FILTERS

The  grease  filters  absorb  grease  and  dust
during cooking to help keep the chimney hood
clean  inside,  and  should  be  cleaned  every
month with normal usage or more frequently
if the hood is used consistently over 4 hours
per day.

Remove  the  metal  grease  filter

cassettes  one  at  a  time,  by  pressing  the
release catch towards the rear of the hood
as  illustrated  opposite.  When  replacing  the
filters ensure that the handle faces forwards.

The metal grease filters can be washed in a
dishwasher or by hand using a mild detergent

or liquid soap.

CHARCOAL FILTER

In  the  recirculation  mode  the  activated
charcoal filter absorbs smells and unwanted
odours.

The  charcoal  filter  cannot  be  cleaned  or
regenerated and must be replaced every four
months, or more frequently if the hood is used
consistently over 4 hours per day.

To  replace  the  charcoal  filter,  first

remove  the  metal  grease  filters  and  press
against the plastic retaining clips to remove

the charcoal filter as illustrated opposite.

We recommend that you wear rubber gloves
when removing the charcoal filter as the filter
will be saturated in grease. Put the filter into
a  polythene  bag  or  container  so  that  the
grease and dirt cannot spill onto clothing of

furnishing.

MAINTENANCE AND CLEANING

THIS  APPLIANCE  CAN  BE  A

POSSIBLE FIRE HAZARD IF THE GREASE
FILTERS  ARE  NOT  CLEANED  AND  THE
CHARCOAL  FILTERS  REPLACED  AS

RECOMMENDED.

Replacement  charcoal  filters  may  be
purchased  by  returning  the  enclosed  order
form, or by telephoning 01803 296155 if you

wish to pay by credit card.

6

Summary of Contents for LEIHDS120SC

Page 1: ...LEIHDS120SC Users Guide Installation Instructions...

Page 2: ...Filters 6 Charcoal Filter 6 Lighting 7 Cleaning 7 INSTALLATION INSTRUCTIONS Technical Information 8 ELECTRICAL CONNECTION Elecrical Requirements 9 Electrical Connection 9 INSTALLING THE CHIMNEY HOOD...

Page 3: ...Height or if the motor becomes overheated If the cut out device is activated switch off the fan motor and allow the cooker hood to cool The cut out device will reset itself when the fan motor has coo...

Page 4: ...recommended Always insist on genuine RANGEmaster spare parts Under no circumstances should you attempt to repair the appliance yourself Repairs carried out by inexperienced persons may cause injury o...

Page 5: ...the canopy BUTTON L Turns the worktop lighting On and Off YOUR APPLIANCE BUTTON V1 Turns the fan On and Off at the low speed setting This is an ideal speed when cooking for long periods as the continu...

Page 6: ...les in either side of the chimney stack into the kitchen EXTRACTION In the extraction mode contaminated air enters the chimney hood through the grease filter cassettes and is passed out through ductin...

Page 7: ...a dishwasher or by hand using a mild detergent or liquid soap CHARCOAL FILTER In the recirculation mode the activated charcoal filter absorbs smells and unwanted odours The charcoal filter cannot be c...

Page 8: ...ps are specified 230V 20W When replacing the spotlamps make sure that the two pins are correctly inserted in the lamp holder and then replace the glass lens and retaining ring CLEANING We recommend th...

Page 9: ...ONSUMPTION 200W FAN 140W SPOTLAMPS 3x20W 60W PERFORMANCE SPEEDS 3 CAPACITY m3 h 550 CAPACIITY m3 h 690 PRESSURE PA 340 INPUT W 200 NOISE LEVEL dBA 67 IEC 61591 method for cooker hoods in evacuation mo...

Page 10: ...voltage corresponds to the voltage on the rating plate inside the cooker hood This appliance is fitted with a 3 core mains cable and must be permanently connected to the electricity supply via a doubl...

Page 11: ...nts for the discharge of exhaust air Incorrect installation may affect the safety of this chimney hood INSTALLATION REQUIREMENTS Before installation check the wall to which the hood is to be fitted fo...

Page 12: ...ALL BRACKETS 1 Draw a vertical line on the wall as illustrated from the centre of the cooking appliance up to the ceiling using a spirit level and marker pen This is to ensure the correct vertical ali...

Page 13: ...the wall Note If the chimney hood is to be installed onto a hollow construction plaster or partition board wall then special fixing screws will be required not supplied FIXING THE CANOPY 1 Before star...

Page 14: ...performance while reducing noise levels The ducting flange B should be sleeved over the spigot A when using 125mm 5ins ducting as the European ducting spigot is 120mm Ducting kits can be obtained from...

Page 15: ...chimney to the two brackets 2 using four of the screws provided with the fixing kit 2 To fit the lower chimney section I first apply pressure to expand the two side panels slightly to allow the chimn...

Page 16: ...4329643 03 020412...

Reviews: