Remote Control Commands
R&S
®
NRX
302
User Manual 1178.5566.02 ─ 07
READ<Measurement>:ARRay[:POWer][:AVG]:SWR?
<buffered_size>[,
<expected_value_or_source_list>, <resolution_or_source_list>, <source_list>...]
MEASure<Measurement>:ARRay[:POWer][:AVG]:SWR?
<buffered_size>[,
<expected_value_or_source_list>, <resolution_or_source_list>, <source_list>...]
CALCulate<Measurement>:MATH[:EXPRession]
"SWR(SENSn,SENSm)"
.
Standing wave ratio measurement of two power sensors with buffering. The used
parameters are described in
Suffix:
<Measurement>
.
1 to 8
Measurement
Query parameters:
<buffered_size>
<expr>
<expected_value_or_source_list>
<resolution_or_source_list>
<source_list>
<expr>
Usage:
Query only
13.6.2.3
Burst Average Calculation Functions
Parameter list
For the calculation functions of the burst average measurement, the following parame-
ters are used.
●
<dtolerance>
Mandatory. Length of a time interval during that the power level can drop below the
trigger level without being interpreted as end of the power pulse.
Corresponds to
[SENSe<Sensor>:][POWer:]BURSt:DTOLerance
●
<start_exclude>
Mandatory. Amount of time at the beginning of a timeslot or integration period that
is not evaluated.
Corresponds to
[SENSe<Sensor>:]TIMing:EXCLude:STARt
●
<end_exclude>
Mandatory. Amount of time at the end of a timeslot or integration period that is not
evaluated.
Corresponds to
[SENSe<Sensor>:]TIMing:EXCLude:STOP
●
<expected_value>
Optional. Value that is expected for the measurement.
●
<resolution>
Optional. Limit up to which the measurement result should be free of noise.
Corresponds to
[SENSe<Sensor>:]AVERage:COUNt:AUTO:RESolution
●
<source_list>
Calculation Functions
www.allice.de
Allice Messtechnik GmbH