LM05 SERIES II I&M MANUAL/EN/11.30.2010
18/89
This document and the information contained herein, is the exclusive property of R&M Materials Handling, Inc., and represents a non-public, confidential and proprietary trade secret that
may not be reproduced, disclosed to third parties, altered or otherwise employed in any manner whatsoever without the express written consent of R&M Materials Handling, Inc.
Copyright © (2010) R&M Materials Handling, Inc. All rights reserved.
5.1.2 Environmental Data
Ambient temperature:
-10°C to +40°C
Protection degree:
IP55 as standard
Sound level:
70 decibels at 1 m
5.1.3
Optional equipment
Limit Switch:
This cuts off the directional movement when the trolley reaches the end of its run.
Electric Actuation Device:
This actuates the supply line; the slide block must not exceed the rolling
profile (A).
Brush:
This allows for earthing, due to the brush rubbing on the profile element.
Raceway Stops:
Not supplied: These must be fitted on the profile element, at the end of the trolley run.