LM05 SERIES II I&M MANUAL/EN/11.30.2010
19/89
This document and the information contained herein, is the exclusive property of R&M Materials Handling, Inc., and represents a non-public, confidential and proprietary trade secret that
may not be reproduced, disclosed to third parties, altered or otherwise employed in any manner whatsoever without the express written consent of R&M Materials Handling, Inc.
Copyright © (2010) R&M Materials Handling, Inc. All rights reserved.
6 SWIVEL TROLLEY
6.1 Description – Technical Characteristics (swiveling trolley to 3.2
tons)
NOTE: The trolley you have just purchased must be used only with the nominal load indicated on
the rating plate.
NOTE: The trolley’s service life will depend on the level of duty, the average operating time, the
number of starts and the maintenance applied to it.
6.1.1
Technical Characteristics
Type 1
Type 2
30 Hz
≤
1000 kg
100 Hz
>1000 kg
Fem Class
H4
H4
IP
IP55
IP55
Insulation class
F
F
Duty factor
40%
40%
Operating temperature
-10°C, +40°C
-10°C, +40°C
Power supply frequency
60 Hz
60 Hz
Standard speed
20/5 m/min 80/20 fpm
20/5 m/min 80/20 fpm
Default acceleration time (Deceleration time)
2.5 s
2.5 s
Thermal protection for motor
Option
Option
Thermal protection for frequency converter
Std.
Std.
Noise level
70 db
70 db