Raisecom Technology Co., Ltd
6
IT provides fault pass function to transfer alarm of line side to V.35 interface so that
to judge E1 line error through router.
Features of the second tributary E1 interface of client side:
It complies with PDH transmission conception to realize the transparent
transmission of E1 data and clock setting in fiber line.
It has all the features of PDH fiber optic modem.
Very large ASIC chip, low consumption, four level PCB design, high reliability.
2.3. Model Description
RC800-60B-FV35 series fiber optic modem includes the following types:
Model Type
Description
RC801-60B-FV35-S1(AC)
Standalone at the Customer Premises, one V.35 interface(M 34),one E1 interface( two BNC and one RJ45), one
Optical interface, SM Dual strand(DSC),0-25km, AC
RC801-60B-FV35-S1(DC)
Standalone at the Customer Premises, one V.35 interface(M 34),one E1 interface( two BNC and one RJ45), one
Optical interface, SM Dual strand(DSC),0-25km, DC
RC801-60B-FV35-S2(AC)
Standalone at the Customer Premises, one V.35 interface(M 34),one E1 interface( two BNC and one RJ45), one
Optical interface, SM Dual strand(DSC),10-60km, AC
RC801-60B-FV35-S2(DC)
Standalone at the Customer Premises, one V.35 interface(M 34),one E1 interface( two BNC and one RJ45), one
Optical interface, SM Dual strand(DSC),10-60km, DC
RC801-60B-FV35-S3(AC)
Standalone at the Customer Premises, one V.35 interface(M 34),one E1 interface( two BNC and one RJ45), one
Optical interface, SM Dual strand(DSC),15-120km, AC
RC801-60B-FV35-S3(DC)
Standalone at the Customer Premises, one V.35 interface(M 34),one E1 interface( two BNC and one RJ45), one
Optical interface, SM Dual strand(DSC),15-120km, DC
RC803-60B-FV35-S1(AC)
Standalone at the Customer Premises, one V.35 interface(M 34),one E1 interface( two BNC and one RJ45), one
Optical interface, SM Single strand 1310(SC-PC),0-25km, AC
RC803-60B-FV35-S1(DC)
Standalone at the Customer Premises, one V.35 interface(M 34),one E1 interface( two BNC and one RJ45), one
Optical interface, SM Single strand 1310(SC-PC),0-25km, DC
RC803-60B-FV35-S2(AC)
Standalone at the Customer Premises, one V.35 interface(M 34),one E1 interface( two BNC and one RJ45), one
Optical interface, SM Single strand 1310(SC-APC),10-50km, AC
RC803-60B-FV35-S2(DC)
Standalone at the Customer Premises, one V.35 interface(M 34),one E1 interface( two BNC and one RJ45), one
Optical interface, SM Single strand 1310(SC-APC),10-50km, DC
RC805-60B-FV35-S1(AC)
Standalone at the Customer Premises, one V.35 interface(M 34),one E1 interface( two BNC and one RJ45), one
Optical interface, SM Single strand 1550(SC-PC),0-25km, AC
RC805-60B-FV35-S1(DC)
Standalone at the Customer Premises, one V.35 interface(M 34),one E1 interface( two BNC and one RJ45), one
Optical interface, SM Single strand 1550(SC-PC),0-25km, DC
RC805-60B-FV35-S2(AC)
Standalone at the Customer Premises, one V.35 interface(M 34),one E1 interface( two BNC and one RJ45), one
Optical interface, SM Single strand 1550(SC-APC),10-50km, AC
RC805-60B-FV35-S2(DC)
Standalone at the Customer Premises, one V.35 interface(M 34),one E1 interface( two BNC and one RJ45), one
Optical interface, SM Single strand 1550(SC-APC),10-50km, DC
RC802-60B-S1
Module type, two E1 interfaces (four BNC or two RJ45), one optical port, SM dual strand (DSC),