background image

 
 

0049-0100-XX2                                                                   MIU9.6FPD  –  USERS GUIDE     

   

  06/22/2010 

Rev. A 

 

 

            

 

 

 

 

 
 

 

 

 
 
 
 
 
 

 
 

 

 
 
 

 

Digital Fast Poll Modem  

 

MIU9.6FPD 

 

USER’S GUIDE 

 
 

Summary of Contents for Telenetics MIU9.6FPD

Page 1: ...0049 0100 XX2 MIU9 6FPD USERS GUIDE 06 22 2010 Rev A Digital Fast Poll Modem MIU9 6FPD USER S GUIDE ...

Page 2: ...0049 0100 XX2 MIU9 6FPD USERS GUIDE 06 22 2010 Rev A Page i Raymar Information Technology Inc 7325 Roseville Road Sacramento CA 95842 800 695 1951 Fax 916 783 1952 ...

Page 3: ...otice and does not represent a commitment on the part of Raymar Telenetics Raymar Telenetics assumes no responsibility for any inaccuracies that may be contained in this User s Guide Raymar Telenetics makes no commitment to update or keep current the information in this User s Guide and reserves the right to make changes to this User s Guide and or product without notice No part of this manual may...

Page 4: ...MIU9 6FPD USERS GUIDE 06 22 2010 Rev A Page iii TABLE of CONTENTS 1 INTRODUCTION Page 1 2 INSTALLATION Page 6 3 APPENDIX A TROUBLESHOOTING Page 15 4 APPENDIX B SPECIFICATIONS Page 18 5 APPENDIX C COMPLIANCES Page 23 ...

Page 5: ... offers a range of data rates from 2400 to 19 200 bps The MIU9 6FPD comes in low voltage and standard voltage models In addition the MIU9 6FPD is internally surge protected on both power and analog lines and operates within the temperature range of 40 C to 85 C The MIU9 6FPD consists of a baseboard and a communication module The baseboard includes the power supply regulation and surge protection T...

Page 6: ...one modem 9 0 to 36 VDC voltage input power supply MIU9 6FPD R LV Single channel standalone repeater 9 0 to 36 VDC voltage input power supply MIU9 6FPD Single channel standalone modem 48 to 120 V AC DC voltage input power supply MIU9 6FPD R Single channel standalone repeater 48 to 120 V AC DC voltage input power supply Note In this User s Guide MIU9 6FPD will be used collectively to refer to all m...

Page 7: ...quires no human intervention making it ideal for unmanned locations Works within an extended temperature range of 40ºC to 85ºC Designed with coupling transformers and opto isolator for high voltage isolation and common mode noise rejection in industrial and commercial environments Provides surge protection superior to those of conventional commercial modems Accepts power from a wide range of AC an...

Page 8: ... with repeater configuration Figure 1 1 Sample Multipoint with Repeater Configuration There are a number of factors that can affect the MIU9 6FPD s operation and performance These include Operating speed Wire gauge size of the transmission line Transmission line characteristics such as noise interference cross talk and distortions Network configuration point to point or multipoint Number of nodes ...

Page 9: ...rations Table 1 2 Operating Distances for Point to Point Configurations Operating Distances Data Rate bps 26 AWG 24 AWG 18 AWG 19 200 8 000 feet 10 000 feet 12 000 feet 9 600 16 000 feet 20 000 feet 25 000 feet 4 800 20 000 feet 25 000 feet 45 000 feet 2 400 34 000 feet 42 000 feet 60 000 feet Table 1 3 Operating Distances for Multipoint Configurations Multipoint 9 600 bps Operating Distance Using...

Page 10: ...A communications interface to the MIU9 6FPD terminal block An appropriate power supply Models MIU9 6FPD LV and MIU9 6FPD R LV accept 9 0 to 36 VDC Models MIU9 6FPD and MIU9 6FPD R accept 48 to 120 V AC DC HARDWARE OVERVIEW Figure 2 1 shows the front view of the modem This view shows Two sets of configuration switches Use the top switches to configure the modem module The bottom switches remain at ...

Page 11: ...ows the back view of the modem This view shows A power interface on the right side for connecting to a voltage source A female 9 pin RS 232 connector on the left side for connecting a standard DTE RTU A red LED between the RS 232 connector and power interface Figure 2 1 Front View ...

Page 12: ...volves the following steps 1 Finding a suitable location for the modem See the section below 2 Configuring the modem module 3 Connecting to a transmission line 4 Connecting to a voltage source 5 Optional Connecting a DTE device Note The back panel of the baseboard has four DIP switches Leave these switches in their factory set positions ...

Page 13: ...nt panel power interface It should also let you view the red and green LEDs on the front panel Note Raymar Telenetics offers a rack mount version of this modem Configuring the Modem Module You configure the modem module using the six DIP switches on the modem front panel and one jumper Figure 2 1 shows the location of the switches and jumper Switch Settings The modem has six front panel DIP switch...

Page 14: ... OFF OFF OFF ON OFF OFF OFF OFF ON Anti streaming prevents slave modems from transmitting continuously and snarling the network For maximum operating distance select 0 dBm For Switches 3 through 6 only one of these switches can be set to the ON position Jumper Setting The modem module has a jumper for selecting the impedance see Figure 2 1 You can access the jumper from the front panel of the PE9 ...

Page 15: ...e Figure 2 1 The single channel standalone modem has one transmission line interface The repeater has two transmission line interfaces The left interface is for connection to a host modem and computer while the right is for a repeater connection If you will not be performing repeater applications do not use the right interface Each transmission line interface is a 4 wire analog connection where on...

Page 16: ...his Signal TB B pin 1 Tx TB B pin 2 Tx TB B pin 3 Rx TB B pin 4 Rx For communications to occur the polarity of the transmit and receive lines from one MIU9 6FPD to another must connect as shown below Tx RX Tx Rx Rx Tx Rx Tx Important Polarity of the transmission line must be followed If connections are reversed no data will be received ...

Page 17: ...he MIU9 6FPD s power interface Note Before you connect to a voltage source Be sure the voltage source is within the permitted range in Table 2 5 Otherwise your MIU9 6FPD and any attached devices may be damaged Customer supplied cables must be suitable for the site environmental conditions Screw terminals on the power interface accept 28 to 16 AWG However surge protection is guaranteed only if the ...

Page 18: ...U such as an IBM or compatible personal computer or VT100 terminal that conforms to the pin assignments shown under RS 232 RTU Interface LEDs The MIU9 6FPD front panel has two LEDs see Figure 2 1 The top LED blinks green when data is being received The bottom LED blinks red when data is being sent The MIU9 6FPD back panel has one red LED see Figure 2 2 This LED Blinks once per second when power is...

Page 19: ...e modem or polarity may be reversed Make sure the transmission line connection to the modem is accurate and secure The modem does not transmit data and the red LED on the front panel does not blink The attached terminal or DTE may not be sending data to the modem Verify that data is being transmitted If data is being transmitted make sure the RS 232 cable is sound and securely connected to the mod...

Page 20: ... A 1 shows the factory set jumper and switch settings for the standard voltage baseboards Models MIU9 6FPD and MIU9 6FPD R Do not change these factory settings Figure A 1 Baseboard Module Switch and Jumper Locations Table A 1 Factory Settings for Low Voltage Baseboard Module This Switch Jumper Has the Following Factory Settings J2 Pins 2 and 3 strapped Pins 6 and 7 strapped Pins 8 and 9 strapped J...

Page 21: ...board Module This Switch Jumper Has the Following Factory Settings J2 Pins 2 and 3 strapped Pins 6 and 7 strapped Pins 8 and 9 strapped J7 Pins 2 and 3 strapped J8 Pins 1 and 3 strapped S1 Switches 2 and 3 ON S3 Switches 1 2 and 4 ON Switch 3 OFF LOOPBACK TEST Loopback Test for Single Channel Loopback Test for Repeater ...

Page 22: ...IU9 6FPD R LV MIU9 6FPD MIU9 6FPD R Width 4 0 inches Length 5 5 inches Height 1 4 inches Weight 9 0 ounces Model PE9 6FPD Width 2 2 inches Length 3 5 inches Height 0 55 inches Weight 1 5 ounces Voltage Supply Models MIU9 6FPD LV and MIU9 6FPD R L 9 0 to 36 VDC Models MIU9 6FPD and MIU9 6FPD R 48 to 120 V AC DC Surge Protection Power Supply 8k Vrms ...

Page 23: ...FPD R LV 1 2 Watts maximum Model MIU9 6FPD Input Supply 48 to 120 V AC DC Power Consumption 1 0 Watt maximum Temperature and Humidity Operating Temperature 40ºC to 85ºC Operating Humidity 0 to 95 non condensing Storage Temperature 55ºC to 125ºC MODEM SPECIFICATIONS Modulation Pulse Position Modulation PPM Data Rate 2400 to 19 200 bps asynchronous Error Correction None Data Compression None Serial ...

Page 24: ... ASSIGNMENTS Model MIU9 6FPD LV and Model PE9 6FPD Analog Interface Pin Number Corresponding Signal TB A pin 1 Tx TB A pin 2 Tx TB A pin 3 Rx TB A pin 4 Rx MIU9 6FPD R LV and MIU9 6FPD R Analog Interface Pin Number Corresponding Signal TB B pin 1 Tx TB B pin 2 Tx TB B pin 3 Rx TB B pin 4 Rx ...

Page 25: ...terface DB9 9 Pin Connector Pin Number Input Outp ut Signal Name 1 Out CD 2 Out RXD 3 In TXD 4 In DTR 5 SG 6 Out DSR 7 In RTS 8 Out CTS 9 Not Used DB25 25 Pin Connector Pin Number Input Outp ut Signal Name 1 FG 2 In TXD 3 Out RXD 4 In RTS 5 Out CTS 6 Out DSR 7 SG 8 Out CD 20 In DTR ...

Page 26: ...0049 0100 XX2 MIU9 6FPD USERS GUIDE 06 22 2010 Rev A Page 22 of 25 PE Module ...

Page 27: ...ference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment to an outlet on a circuit other than the one to which the receiver is co...

Page 28: ...RICE OF THE PRODUCT FOR ANY LOSS OF USE LOSS OF TIME INCONVENIENCE COMMERCIAL LOSS LOST PROFITS OR SAVINGS OR OTHER INCIDENTAL SPECIAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OR INABILITY TO USE THIS RAYMAR PRODUCT TO THE FULL EXTENT SUCH MAY BE DISCLAIMED BY LAW WITHOUT LIMITING THE FOREGOING RAYMAR SHALL HAVE NO LIABILITY FOR ANY DATA STORED IN OR USED WITH THE PRODUCT INCLUDING THE RECO...

Page 29: ...ber the serial number a description of the problem being encountered and the cause of the problem if known Please note that prior to authorizing a return a product support specialist may call to verify that the product is properly installed or may ask you to perform tests to insure that the product has actually failed The product must be properly packed and returned to Raymar Telenetics 7325 Rosev...