Raisecom Technology Co., Ltd
23
5. Installation & Preparation
5.1. Before installation
Please make sure that your V.35 cable matches the equipment you want to connect
Please check whether the equipment has been destroyed
If you do not use network management, please configure the device through
DIP-switch before installation.
The E1 interface is 75
Ω
BNC in default, if Balance interface is needed please
configure the SW7 on the bottom of device.
Using of E1 balanced interface cable
The definition of each pin on E1 balanced interface is
shown in below table:
PIN
NO.
1 2 3 4 5 6 7 8
Signal
Name
TD+ TD- N/A RD+ RD- N/A N/A
N/A
Meaning Output -
-
Input +
Input -
-
-
-
When connect the 120
Ω
balanced interface to other device, the pin definition of the device
should be aware. The connection type of twisted pair cable is shown as following:
Modem
BALANCE-RJ45 E1Transmission Device Balanced Interface
TD
+
Signal Output
+
TD
-
Signal Output
-
RD
+
Signal Input
+
RD
-
Signal Input
-
NOTE: The TD+ and TD- should be two lines which are twisted together. And it is the
same to RD+ and RD-.
5.2. Cautions before Applying the Power Supply
It is strictly forbidden to hot-swap the V.35 interface cable.
If adopts the DC –48V power supply, please firstly connect the Protecting Ground (the
middle pin PGND). They must not be reversely connected, connect -48V with low
voltage input, BGND with high voltage input.
1
st
Pin
8
th
Pin