Revision: 2.1a

User's Manual

Summary of Contents for SDTU-01/ET10

Page 1: ...Revision 2 1a User s Manual ...

Page 2: ......

Page 3: ...n nt ts s 1 Overview 1 2 Features 1 3 Packaging 1 4 Appearance 2 5 Hardware Installation 3 6 Management 4 7 Default values 5 8 Software Upgrade 6 Appendix A Console Setup 7 Appendix B Command Line Interface 8 Appendix C Specifications 43 Hardware Specifications 43 Software Specifications 44 ...

Page 4: ...LLATION 3 FIGURE 4 COMMAND TREE 9 R Re ev vi is si io on n M Ma ar rk ks s Manual Revision Date Notes V2 0 May 25 2000 Software V2 11B H30 02 F45 108 l Original revision V2 0a June 05 2000 Software 2 50B H30 02 F45 111 V2 01 July 06 2000 Software 2 16R H20 02 F45 111 V2 1 July 24 2000 Software 2 17R H20 02 F45 111 V2 1a Sept 13 2000 Software 2 15RX H13 3002 F45 121 ...

Page 5: ...sion on Single Twisted Copper Pair Wire ü 2B1Q Line Coding ü Symmetrical Multi rate data transmission from 144Kbps up to 2320Kbps ü RFC 1483 Bridging over ATM over SDSL ü IPoA and PPPoA Routing over ATM over SDSL ü 4 x 10BaseT Ethernet Ports for PC LAN ü High quality simple operation low power consumption ü Compatible and interoperable with major Central Office side SDSL DSLAM or Multi service Acc...

Page 6: ...ort is connected Blink while transmitting or receiving packets Red LED on when Ethernet collision occur WAN Status Blinks while training with DSLAM and On when SDSL link is ready Power On when the power supply is properly connected Activity Blinks while transmitting or receiving packets over one of Ethernet ports LINK Status On when one of Ethernet ports is properly connected to a LAN or PC Alarm ...

Page 7: ...rossover cable while connecting to a hub 3 Plug in the AC adapter to the AC power socket then connect the DC jack as 3 indicated in Figure 3 to the DC inlet of the SDTU 01 ET10 4 Use a 9 pin RS232 cable as 4 indicated in Figure 3 to connect the Console Port to a serial port of a terminal such as PC with data terminal emulation software Hyper Terminal installed in order for local management Figure ...

Page 8: ...local area network or to a PC directly Telnet SDTU 01 ET10 from any workstation in the LAN The default local Ethernet IP address is 192 168 2 1 ü SDSL port from remote site while SDSL connection is in service you may remotely Telnet SDTU 01 ET10 from a workstation networking to the CO equipment the default Remote Ethernet IP address is 192 168 1 1 Note As operating SDSL modem requires technical kn...

Page 9: ...d SDSL Ethernet local IP 0 0 0 0 Side select CPE RT side Subnet mask 0 0 0 0 Auto Rate disable Protocol RFC1483 bridge Mode Rate select 2320K VPI VCI 8 35 Sign Magnitude Bit Sequence normal Class level QoS UBR Data Bit Polarity Normal PCR Peak cell rate 640 Scrambling enable Spanning tree disable Idle cell sending enable Packet control IP and PPPoE DHCP setting Max lease time 86400 seconds ...

Page 10: ...n successfully ping SDTU 01 ET10 The default local and remote IP addresses are 192 168 2 1 and 192 168 1 1 respectively ü Under DOS prompt execute command xupgrade IP address of SDTU 01 ET10 for instance xupgrade 192 168 1 1 ü This upgrading process might last as long as 60 seconds ü Then reboot SDTU 01 ET10 with new software NOTE Strictly maintain stable power to SDTU 01 ET10 while upgrading soft...

Page 11: ...Group à Double Click Hypertrm exe à Enter Connection Name à Select Icon à Click OK 2 Select COM port to communicate with SDTU 01 ET10 Choose direct to COM1 or COM2 à click OK 3 Set Port Properties 4 Port Setting Bit per second 9600 Data bits 8 Stop bits 1 Parity bits None Flow Control None 4 Settings Function arrow and ctrl keys act as Windows keys Emulation Auto detect Back scroll buffer lines 50...

Page 12: ...nclose in are compulsory means the parameter that is enclosed is optional and between parameters means either or In the parameters section means the parameters that enclose in are Key Word Furthermore after entering the password screen will show the prompt as for enter the command There are two hierarchical levels in the command line interface The command tree below will show the hierarchical rela...

Page 13: ...setqos setwanip show dhchpclient dhcpserver setdhcp setip show setpass addpatin delpatin setpat show adduser chpass deluser setqos show delpvc pfilter setpvc setqos setspan show rtable addiproute deliproute show auto cell dbit default enable rate scramble status terminal smbit Figure 4 command tree ...

Page 14: ...y the description and usage of particular command in each level Syntax Help command Parameters command Enter each command Example Response sdsl help terminal Display the description and syntax of terminal command terminal Configure the device to COE or CPE mode Usage terminal coe cpe coe COE mode is selected cpe CPE mode is selected Syntax command Parameters command Enter each command Example sdsl...

Page 15: ...mode is selected HOME Go back to the upper level menu Syntax home Parameters Example home MAIN MENU COMMANDS default ipoa lan list manage pat ping pppoa quick r1483 restart rtable save sdsl show ver DEFAULT Set all configuration to factory setting Syntax Default Parameters Example Response default Set to default successfully ...

Page 16: ...Display the status for each enabled VC Syntax List Parameters Example Response Explanation Explanation list Port ethernet 0 Enabled TxPkts 1 RxPkts 0 0 Port sdsl 1 Enabled TxPkts 56 RxPkts 37 0 TxVPI VCI 0 35 RxVPI VCI 0 35 Information for Ethernet port 0 Status of port number 1 Enabled TxPkts transmitted packets 1 RxPkts received packets 0 0 correct error Information for SDSL port 1 Status of por...

Page 17: ...manage PAT Enter to PAT configuration menu More commands under PAT menu see detail after Syntax pat Parameters Example pat PING Ping a specific IP address for testing purpose Syntax ping ipaddress Parameters ipaddress IP address in the format of 4 decimals separated by dots Example1 Response Explanation Example2 Response Explanation ping xxx xxx xxx xxx ip ping reply received from xxx xxx xxx xxx ...

Page 18: ...to PPPOA menu More commands under PPPOA menu see detail after Syntax Pppoa Parameters Example pppoa QUICK Enter VC with RFC1483 IPoA PPPoA mode by an interactive user interface Syntax Quick Parameters Example Response quick R1483 r IPoA i PPPoA p r Enter 1 PVC existed quick R1483 r IPoA i PPPoA p i Enter 0 PVC existed 8 PVCs available Ethernet IP 210 62 2 134 Enter Subnet mask 255 255 255 0 Enter ...

Page 19: ...210 62 5 175 Enter Add another PVC y n n Enter Setup Configuration FUNCTION IPOA Ethernet IP 210 62 2 134 Subnet Mask 255 255 255 0 VPI VCI WAN IP RIP Gateway IP 1 8 32 210 62 5 183 1 2 2 32 210 62 5 187 210 62 5 175 Preserve the configuration y n n Enter Continue quick y n y Enter R1483 r IPoA i PPPoA p p Enter 0 PVC existed 1 PVC available Ethernet IP 210 62 2 134 Enter Subnet mask 255 255 255 0...

Page 20: ...62 2 134 Subnet Mask 255 255 255 0 VPI VCI AUTH USERID 1 6 33 PAP xavi Preserve the configuration y n n Continue quick y n n Configuration will have no effect until after save and restart R1483 Enter to R1483 menu More commands under R1483 menu see detail after Syntax r1483 Parameters Example r1483 RESTART Reboot the SDSL modem Syntax restart Parameters ...

Page 21: ... SDRAM size 0x800000 type 0x5 Booting System start RTABLE Enter to RTABLE menu More commands under RTABLE menu see detail after Syntax rtable Parameters Example rtable SAVE Save the configuration into flash memory and restart the modem Syntax save Parameters Example save Save configuration then reboot the modem ...

Page 22: ... enabled VC and Ethernet Syntax show Parameters Example Response show Ethernet ip 210 62 2 134 Subnet mask 255 255 255 0 DHCP Server setup range1 0 0 0 0 to 0 0 0 0 max lease time 86400 DHCP Client setup lease time 900 retry 2000 reboot 500 backoff cutoff 240 timeout 300 DHCP auto mode waiting time is 0 DHCP setup Now is disable DHCP setup is set to Client mode ...

Page 23: ...he PPPoA dial out setting Function VPI VCI CLASS PCR KBits UserID Authentication PPPoA 2 32 ubr 640 xavi CHAP Routing Table No Destination IP SubMask Gateway IP 1 192 62 2 0 255 255 255 0 210 62 2 135 PAT enabled interface Interface IP address IPoA 210 62 2 195 PPPoA PAT incoming table No i f name WanIP Port Protocal Server IP 1 pppoa 434 udp 192 62 2 134 2 210 62 2 195 232 tcp 192 62 2 166 Inform...

Page 24: ...imeout time 300 seconds Information for IPoA setting Function Protocol in use IPoA VPI VCI Connected VC channel 8 32 CLASS define QoS on the ATM network ubr PCR Peak Cell Rate 0 cells per second Wan IP WAN IP address 192 168 2 2 GatewayIP Gateway IP address 192 168 2 183 RIP routing information protocol 0 0 Static routing method 1 2 1 2 dynamic routing method Information for PPPoA setting Function...

Page 25: ...Pkt Filter packet control Any Allow to pass both IP and PPPOE packet Note IP only allow to pass IP packet PPPoE only allow to pass PPPoE packet Information for routing table setting No routing table number assign by system 1 Destination IP 192 62 2 0 SubMask subnet mask 255 255 255 0 Gateway IP 210 62 2 135 Information for PAT each enabled interface IPoA protocol in use and enabled interface IP ad...

Page 26: ...eters Example ver IPOA LEVEL COMMANDS Delwanip setqos setwanip show DELWANIP Disable VC by giving a VPI and VCI numbers defined by setwanip command previously User can set up to 8 PVC in IPoA configuration Syntax delwanip all vpi vci Parameters all delete all routing information vpi decimal value of VPI number 0 to 4095 vci decimal value of VCI number 1 to 65535 Example ipoa delwanip 1 32 Disable ...

Page 27: ...per second for the connection SETWANIP Enable a VC by giving a VPI and VCI numbers also assign a WAN IP and gateway IP address for static routing or selecting RIP for dynamic routing Note wanip and gatewayip must be in the same subnet mask Syntax setwanip vpi vci wanip gatewayip rip 1 2 1 2 Parameters vpi decimal value of VPI number 0 to 4095 vci decimal value of VCI number 1 to 65535 wanip WAN IP...

Page 28: ...br 0 210 62 2 198 210 62 2 185 0 Information for IPoA setting Function Protocol in use IPoA VPI VCI Connected VC channel 8 32 CLASS define QoS on the ATM network ubr PCR Peak Cell Rate 0 cells per second Wan IP WAN IP address 192 168 2 2 GatewayIP Gateway IP address 192 168 2 183 RIP routing information protocol 0 0 Static routing method 1 2 1 2 dynamic routing method LAN MENU COMMANDS dhcpclient ...

Page 29: ...ge of IP addresses that are associated with a subnetwork used for DHCP server Notice the IP addresses should be in the same subnet Syntax dhcpserver range1 startIP range1 endIP range2 startIP range2 endIP max lease time Parameters range1 startIP the first IP address in range 1 for a particular subnetwork in the format of 4 decimals separated by dot range1 endIP the last IP address in range 1 for a...

Page 30: ... waiting time the unit will change to DHCP server automatically waiting time the default is 30 seconds and minimum waiting time is 10 seconds Example lan setdhcp auto 40 Select the unit as DHCP auto mode and waiting time is 40 seconds SETIP Setup IP address and subnet mask for the Ethernet LAN connection Syntax setip etherip subnet mask dhcp Parameters etherip Ethernet IP address in the format of ...

Page 31: ...Server setup range1 0 0 0 0 to 0 0 0 0 max lease time 86400 DHCP Client setup lease time 900 retry 2000 reboot 500 backoff cutoff 240 timeout 300 DHCP auto mode waiting time is 0 DHCP setup Now is disable DHCP setup is set to Client mode Information for Local Ethernet IP subnet mask Ethernet IP local 210 62 2 134 Subnet mask 255 255 255 0 Information for DHCP server setting Range1 First IP to last...

Page 32: ...ers Up to 18 alphanumeric characters Upper case and lower case are different numbers Example 1 Response Explanation Example 2 Response For enabling a new password manage setpass The password is disabled New Password Confirm password again Password has been changed and will be effective only after save Saving configuration Configuration saved You will be asked to key in new password and confirm the...

Page 33: ...ved You will be asked to key in old password and press enter to disable old password and confirm it again PAT MENU COMMAND addpatin delpatin setpat show ADDPATIN Configure a local IP address in the particular server into a global IP address Syntax addpatin pppoa wanip port udp tcp serverip Parameters pppoa or wanip select one of link protocol to configure PAT address wanip WAN IP address defined b...

Page 34: ...ne decimals using show command to check this number assign by system when the user add PAT address Example pat delnatin all Delete all PAT address configuration SHOW Display the PAT configuration Syntax show Parameters Example Response Explanation pat show PAT enabled interface Interface IP address IPoA 210 62 2 195 PPPoA PAT incoming table No i f name WanIP Port Protocal Server IP 1 pppoa 434 udp...

Page 35: ...ddress 192 62 2 134 PPPOA MENU COMMAND Adduser Chpass deluser setqos Show ADDUSER Enable a VC by giving a VPI and VCI numbers also Configure user ID and authentication protocol for security negotiation Syntax adduser vpi vci userid chap pap none Parameters vpi decimal value of VPI number 0 to 4095 vci decimal value of VCI number 1 to 65535 userid User ID chap and pap choose authentication protocol...

Page 36: ...w Password Confirm password again Password has been changed You will be asked to key in old password Type the new password and confirm the new password again DELUSER Delete User ID configuration defined by adduser previously Syntax deluser Parameters Example pppoa deluser Delete user ID configuration SETQOS Configure each enabled VC in PPPoA that should use UBR CBR or VBR define the Quality of Ser...

Page 37: ... Display the configuration of PPPoA routing setting Syntax show Parameters Example Response Explanation pppoa show The PPPoA dial out setting Function VPI VCI CLASS PCR KBits UserID Authentication PPPoA 2 32 ubr 640 xavi CHAP Information for PPPoA setting Function Protocol in use PPPoA VPI VCI Connected VC channel 2 32 CLASS define QoS on the ATM network ubr PCR Peak Cell Rate 0 cells per second U...

Page 38: ...value of VCI number 1 to 65535 vpi vci defined by setpvc command previously any Allow to pass both IP and PPPOE packet ip only allow to pass IP packet pppoe only allow to pass PPPoE packet Example r1483 pfilter 1 32 ip Allow to pass IP packet only in a specific 1 32 VC SETPVC Enable a VC by giving the VCI and VPI numbers Syntax setpvc vpi vci Parameters vpi decimal value of VPI number 0 to 4095 vc...

Page 39: ...reviously ubr Unspecified Bit Rate cbr Constant Bit Rate vbr Variable Bit Rate pcr Peak Cell Rate 0 to 800 cells per second Example r1483 setqos 1 32 ubr 640 Configure 1 32 VC using UBR and 640 cells per second for the connection SETSPAN Enable or disable Spanning Tree under Bridge mode for all enabled VC Syntax Setspan Enable Disable Parameters Enable enable spanning tree Disable disable spanning...

Page 40: ...to pass IP packet PPPoE only allow to pass PPPoE packet RTABLE MENU COMMANDS addiproute deliproute show ADDIPROUTE Configure a destination IP to a specific gateway IP at routing table Note user has to configure the WAN IP and gateway IP at ipoa setwanip command in advance Syntax addiproute destip submask gatewayip Parameters destip destination IP address in the format of 4 decimals separated by do...

Page 41: ...d to check this number assign by system when the user add routing table Example rtable deliproute all Delete all routing information in the routing table SHOW Display the routing table configuration Syntax show Parameters Example Explanation rtable show Routing Table No Destination IP SubMask Gateway IP 1 192 62 2 0 255 255 255 0 210 62 2 135 Information for routing table setting No routing table ...

Page 42: ...e function enable enable auto baud rate function Example sdsl auto enable Enable auto band rate function CELL Enable or disable the idle cell header Syntax cell enable disable Parameters enable enable idle cell header disable disable idle cell header Example sdsl cell enable Enable idle cell header DBIT Configure the SDSL data bit to normal or reverse polarity Syntax dbit normal reverse Parameters...

Page 43: ... The default terminal cpe auto disable rate 2320 smbit reverse dbit normal scramble enable cell enable ENABLE Activate the last updated SDSL parameters without saving and restarting system Syntax enable Parameters Example sdsl enable RATE Manually configure the SDSL line rate Syntax rate n 8 Parameters N 8 144 to 2320 decimal value of rate Kbps step by 8 Kbps i e 160K 20 8K Example 1 sdsl rate 160...

Page 44: ...ble enable Enable scrambling on ATM cell SMBIT Configure the sign magnitude bit sequence Syntax smbit normal reverse Parameters normal normal sign magnitude bit sequence reverse reverse sign magnitude bit sequence Example sdsl smbit normal Configure sign magnitude bit to normal sequence STATUS Display the configuration and status of current SDSL setting Syntax status Parameters Example Response sd...

Page 45: ...ber Ver1 08 SDSL module SDSL interface enable enable normal operation disable malfunction Information for SDSL line status Bitpump F W version SDSL firmware version number 4 5 Bitpump status of chipset present present normal operation unpresent malfunction CO RT select terminal cpe Auto rate auto disable Rate line rate 2320Kbps Sign magnitude bit sequence smbit reverse Data bit polarity dbit norma...

Page 46: ... modem to COE or CPE terminal Syntax terminal coe cpe Parameters coe central office equipment cpe remote terminal Example sdsl terminal coe Configure unit as central office equipment in order for point to point application ...

Page 47: ...peration in faulty status Link Green LED physical connection at LAN data link Act Green LED transmitting receiving data over LAN data link WAN Green LED SDSL data link status Collision Red LED Ethernet collision indication n OAM P Local RS 232 Craft Port Telnet via local Ethernet Remote SNMP Telnet via SDSL n Environment Temperature 0 C 50 C Humidity 5 95 n Physical Dimensions WxDxH 220mm X 169mm ...

Page 48: ... for RFC1483 bridge 8PVCs for IPoA routing and 1 PVC for PPPoA routing Support UBR CBR VBR IP over ATM PPP over ATM n Bridging Transparent Bridging IEEE 802 1D RFC 1483 Spanning Tree Protocol IEEE 802 1D IP and or PPPoE filtering n Management Telnet SNMP MIB II ILMI TFTP ...

Page 49: ...45 ...

Page 50: ... Co Ltd Far Eastern Edison Science and Technologies Center Nei Hu HI TEC Park 6F 3 Lane 360 Nei Hu Road Section 1 Nei Hu Taipei Taiwan Phone 886 2 2659 1021 Rep Fax 886 2 2799 1355 E mail ctcu ms2 hinet net http www ctcu com ...