Ethernet Access 

Residential Unit 110X 

(1103/1104) 

 

 

 

Please read this manual carefully before operating your set. 

Retain it for future reference.   

Summary of Contents for EARU 1103

Page 1: ...Ethernet Access Residential Unit 110X 1103 1104 Please read this manual carefully before operating your set Retain it for future reference ...

Page 2: ...C O N T E N T S 3 Product and personal safety guidelines 8 Regulatory information 11 About EARU 110X 16 Checking package contents 17 Installing EARU 110X 24 Setting EARU 110X ...

Page 3: ...to work on the equipment Audience Personnel working directly on equipment must be trained authorized and qualified to carry out the tasks required able to follow safety guidelines specific to the product and all local customerspecific safety procedures Precautionary messages To prevent personal injury equipment damage and service interruptions you must follow all precautionary messages in LG Norte...

Page 4: ...ss 1 IEC Class I FDA product regardless of the power transmitted within the optical fiber If you have unterminated optical cables breaks in the fiber optic cable or disconnected connectors the output from circuit packs containing optical transmitters does not exceed Class 1 IEC Class I FDA and is therefore considered safe under all reasonably foreseeable conditions The following text includes addi...

Page 5: ... alcohol and prevent contamination of the ferrules with skin oils Place all optical fiber clippings in a plastic container provided for that purpose Handle optical fibers with caution Place the optical fibers in a safe location during installation Protect all optical fiber connectors with clean dust caps at all times Follow the manufacturer instructions when you use an optical test set Incorrect c...

Page 6: ...llowing Report the location of the damaged optical fiber to both the service provider and the field repair personnel Power down all laser sources to the optical fiber or disconnect the remote optical fiber end from the laser sources Working with power Other Warnings and cautions WARNINGS ...

Page 7: ...epair services for this product under specified conditions This warranty does not cover failure or damage of the product caused from using a power adapter other than the one provided PC failures data loss or negligent treatment of the product ...

Page 8: ...n be provided upon request Compliance to applicable technical standards and regulations The EARU 110X meets or exceeds the following standards and requirements CFR Title 47 Chapter 1 FCC Part 15 Subpart B Class B USA ICES 003 Issue 4 Class B Canada European Union EMC Directive 2004 108 EC European Low Voltage Directive 2006 95 EC EN 55022 2006 Class B European Community Australia and New Zealand E...

Page 9: ...measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected consult with the service provider before proceeding Consult the service provider or an experienced radio TV technician for help Repairs to certified equipment should be coordinated by ...

Page 10: ...and EN 300 386 V1 3 3 Class B in respect of the EMC regulatory arrangements of the Radiocommunications Act 1992 of the Australian Communications And Media Authority in particular the Radiocommunications Labelling Electromagnetic Compatibility Notice 2008 and of the New Zealand Ministry of Economic Development The product bears the C tick mark as illustrated in figures on page14 A signed Declaratio...

Page 11: ...ing Passive Optical Network This product multiplexes 125Mbps to 100Mbps Fast Ethernet signals maximum 4ea into WDM PON optical signal This product will allow you to use the different services such as VoD Video on Demand EoD Education on Demand speed internet access available from your provider Names and functions of each part Front view Closed view ...

Page 12: ...Open view ...

Page 13: ...ed OFF Check power supply BATT Battery display Green ON Link Blink activity DATA PON display Red ON Link Blink activity POTS POTS display Green ON Off Hook Blink Ringing Green ON Link Blink activity L E D FE in RJ 45 Ethernet display Yellow ON 100Base T OFF 10Base T BATT Power input Port for the Battery interface ETH1 4 For connection to Ethernet Ethernet ports that will connect to user devices su...

Page 14: ...Labels Number item Label Location 1 CLEI Label 9 652mm x 27 94mm Side 2 PEC SN Label 9 652mm x 27 94mm Side 3 Regulatory 40mm x 81mm Side ...

Page 15: ......

Page 16: ...er DC 12V 2A Ambient Temperature 40 to 65 Humidity 20 to 80 Technical standards EN 300 386 ClassB other then Telecom Centres FCC part 15 CFR 47 Class B EN 55022 Class B 55024 Data rate 100Mbps Connectors SC APC optical RJ45 Ethernet RJ11 POTS LED indicators PWR BATT FAIL LOS L A ...

Page 17: ... Mounting packaging list The mounting kit is optional according to your installation invironment Wall mounting kit list No Item Name Quantity Item Number 1 POLE MOUNTING BRACKET 1 M05801 00 2 SCREW BN660 5 25 2 P04963 00 3 TAPPING SCREW 4 BN695 5 5 32 4 SPRIAL PLASTICPLUG 4 BN309 8 38 5 WASHER BN670 5 2 P04962 00 6 WALL MOUNTING KIT INSTALLATION 1 N04646 00 7 AIR CAP VINYL BAG 1 8 ZIPPER VINYL BAG...

Page 18: ...Quantity Item Number 1 POLE MOUNTING BRACKET 1 M05801 00 2 CLAMP 2 M05815 00 3 SCREW BN660 5 25 2 P04963 00 4 WASHER BN670 5 2 P04962 00 5 POLE MOUNTING KIT INSTALLATION 1 M05816 00 6 AIR CAP VINYL BAG 2 7 ZIPPER VINYL BAG 2 8 VINYL BAG 1 ...

Page 19: ...ent where the following specifications are met Operating temperature 40 to 65 Relative humidity 20 to 80 Power consumption 1 8A Outdoor 12Vdc Input voltage 2A Outdoor DC Power Preparing for installation Before you install the EARU 110X review following information Item Quantity Supplied Main body of EARU 110X 1 yes DC Battery Interface Connect 1 yes Ethernet RJ 45 POTS RJ 11 as required no Optical...

Page 20: ...method Wall mounting No Item Name Quantity Item Number 1 EARU110X BODY 1 2 POLE MOUNTING BRACKET 1 M05801 00 3 SCREW BN660 5 25 2 P04963 00 4 TAPPING SCREW 4 BN695 5 5 32 5 SPRIAL PLASTICPLUG 4 BN309 8 38 6 WASHER BN670 5 2 P04962 00 ...

Page 21: ...back of the pole mounting bracket and then tighten the straps backward the pole with hand No Item Name Quantity Item Number 1 EARU110X BODY 1 2 POLE MOUNTING BRACKET 1 M05801 00 3 CLAMP 2 M05815 00 4 SCREW BN660 5 25 2 P04963 00 5 WASHER BN670 5 2 P04962 00 ...

Page 22: ... tighten the nut 3 5N m Step3 After tightening the nut bend the strap at the other side Step4 Cut the remaining part of strap suitably and then put the end of strap into the rod bolt at the the other side Step5 After mounting the bracket on the pole tighten the screw on the top and bottom of the enclosure with the door open ...

Page 23: ...unding screw on the rear side of the EARU 110X see following picture STEP2 Attach the 1 hole lug using the screw that was removed in STEP 1 The grounding connection is suitable for terminating a 18 AWG wire GROUNDING SCREW 1 HOLE LUG ...

Page 24: ... Battery Low when operating from utility line Open when operating from battery REP Replace Battery Low when battery is charged Open when battery fails the Self Test MIS Battery Missing Low when battery is present Open when battery is missing LOW Low Battery Low when battery is near full charge capacity Open when operating from a battery with 20 capacity BATTERY INTERFACE ...

Page 25: ...sert the SC APC connector from RN distributor into the lower optical port of the EARU 110X Insert the SC APC connector from OTX Module distributor into the lower optical port of the EARU 110X Upper optical port Lower optical port ...

Page 26: ...hernet port numbered ETH1 to ETH4 in EARU 110X Connecting Telephone cable Connect PCM cables to the PCM ports in EARU110X Connect Telephone cables from PCM ports to RJ11 POTS port numbered TEL1 to TEL4 in EARU 110X 4 Ethernet ports 4 Telephone ports 8 PCM Terminals ...

Page 27: ... devices When EARU 110X is power fed the Green and Yellow LEDs should be on The green LED is the data indicator It blinks when data is being transmitted or received The Yellow LED is the link indicator It lights up with a 100Mbps connection If there is a 10Mbps connection a 10BaseT connection the Yellow LED is off Green Yellow Tieing points ...

Page 28: ... do not have to make additional settings on the product to use it Using Internet With a web browser such as the Internet Explorer on your PC you can surf freely through the Internet Note EARU 110X does not require any access program Use your regular internet browser ...