7
GB
It is important that the gas fireplace is correctly installed
with consideration to the environment and people’s
safety. No unauthorised alterations may be made to
the fireplace.
The fireplace may not be used if the glass is split,
cracked, or removed. Do not use the fireplace if the
glass gasket is broken or worn.
Flue systems that are CE approved for this product may
be used (see the following balanced flue manual, page
34).
This fireplace is designed for a balanced flue system (air
intake and extraction in the same chimney). Therefore,
there is no need for an extra air supply for combustion.
It is recommended that the air replacement in the room
is adjusted to ensure a pleasant indoor environment.
This fireplace can be installed in an airtight building
or in a building with mechanical ventilation since the
gas fireplace functions in a closed system that does not
affect the indoor climate of the room.
Please be aware that not following the instructions in
this manual and the provided manuals can lead to a
dangerous or fatal situation.
INTRODUCTION
INTRODUCTION
SAFETY
WARNING!
•
The appliance must be positioned and connected as a room sealed system appliance by an authorised installer.
•
Before beginning the installation, check that the details on the information label correspond to the gas type and
supply pressure to which the appliance will be connected.
•
Install the appliance in accordance with the following instructions, and the national and local applicable regulations.
•
Do not put flammable or organic material in the fireplace.
•
After the fireplace has been shut down, the fireplace needs a cooling period of 15 minutes before the glass can be
removed or cleaned.
•
Make sure that the area around the fireplace is always free of flammable materials. See minimal safe distance from
page36.
•
Make sure that the fireplace stays clean from, e.g. dust and moisture during the installation. Blockage of the delayed
ignition flaps can lead to a dangerous situation.
•
Make sure that the delayed ignition flaps are functional during installation (see page 43).
•
Make sure that the balanced flue is correctly installed.
•
Make sure that the GV60 Combination Valve, the piping, and the top of the fireplace remain free of cement or other
building materials. Otherwise, this can lead to a leak or defective components.
•
Do not twist or force the flexible pipes to the GV60 combination valve. Make sure there is no stress on the pipes.
•
Make sure not to damage the pipes during installation or placement of the fireplace.
•
Make sure that the compression fittings do not come lose doing installation.
•
Do not place the fireplace against a flammable rear wall.
•
After installation, make sure that the pipes, and compressions fittings are gas tight.