18
2575
Visio Gas 100 F
Visio Gas 100 LC
Visio Gas 100 RC
Visio Gas 100 3S
(VISIO 8)
0359
C
11
C
31
C
91
Gas category and supply pressure
Input
(Hi, kW)
Output
(Hi, kW)
Burner
pressure high
(Hot)
Country of destination
L
P
G
I3+ (28-30/37)
G30@28-30
mbar
11,7
9,4
27,2
Interval
24,5 - 29,6
BE, CH, CY, CZ, ES, FR, GB,
GR, IE, IT, PT, SI, SK, TR
I3+ (28-30/37)
G31@37 mbar
11,2
8,9
36
32,4 - 39,6
BE, CH, CY, CZ, ES, FR, GB,
GR, IE, IT, PT, SI, SK, TR
I3P (30)
G31@30 mbar
9,9
7,9
28
25,2 - 30,8
FI, NL, RO
I3P (37)
G31@37 mbar
11,2
8.9
36
32,4 - 39,6
BE, CH, CZ, ES, FR, GB, GR,
HR, IE, IT, LT, NL, PL, PT, SL,
SK, TR
I3P (50)
G31@50 mbar
11,2
8,9
36
32,4 - 39,6
AT, CH, CZ, DE, NL, SK
I3B/P (30)
G30@30 mbar
11,7
9,4
27,2
24,5 - 29,6
BE, BG, CY, DK, EE, FI, FR,
GB, GR, HR, HU, IT, LT, MT,
NL, NO, RO, SE, SI, SK, TR
I3B/P (30)
G31@30 mbar
9,9
7,9
28
25,2 - 30,8
BE, BG, CY, DK, EE, FI, FR,
GB, GR, HR, HU, IT, LT, MT,
NL, NO, RO, SE, SI, SK, TR
I3B/P (50)
G30/G31@50
11,2
8,9
36
32,4 - 39,6
AT, CH, CZ, DE, FR, SK
N
A
T
U
R
A
L
G
A
S
I2H/
I2E
G20 @ 20 mbar
10,3
8,3
18,6
Interval
16,7 - 20,5
AT, CH, CZ, DE, DK, EE, ES,
FI, GB, GR, HR, IE, IT, LT, LU,
LV, NO, PL, PT, RO, SE, SI,
SK, TR
I2ELL
G25 @ 20 mbar
8,3
6,7
18,5
16,7 - 20,4
DE
I2E+
G20@20 mbar
10,3
8,3
18,6
16,7 - 20,5
BE, FR
I2E+
G25@25 mbar
9,3
7,5
22
19,8 - 24,2
BE, FR
I2L / I2EK / I2
(43.46-45.3 MJ/m3 0c)
G25.3 @ 25 mbar
9,4
7,6
21,5
19,4 - 23,7
NL
TOWN GAS
G150.1 @ 8 mbar
5,9
4,4
4,4
Interval
4 - 4,8
DK, SE
G150.1 @ 10 mbar
6,9
5,3
5,3
4,8 - 5,8
DK, SE
This appliance must be installed in accordance with the rules in force, and only used in a sufficiently ventilated space. Consult
instructions before installation and use of this appliance. Tested and Certified for use on Biopropane. Efficiency class 1.
Serial number
Burner ID.
CE Label for:
Visio Gas 22-06-2023
THE GAS FIREPLACE IN GENERAL
This RAIS product is a highly efficient gas fireplace
with a sealed combustion chamber for a balanced flue
system. The fireplace has variable heating power and is
fitted with a burner developed using the latest burner
technology.
BEFORE INSTALLATION
All local regulations and provisions must be studied
before installation. Always check the national building
and gas regulations.
In addition, it should be confirmed that the description
on the information label relating to gas type and gas
pressure is in accordance with the local regulations. The
gas supply should be examined to ensure that it can
supply the required amount of gas and the required
pressure.
It is recommended that gloves are worn when installing
the gas fireplace to avoid fingerprints on glass, etc.
GAS CONNECTION
This gas fireplace may only be installed, adjusted, and
serviced by an authorised installer. The installation
must comply with local and national building and gas
regulations, and the instructions in the installation
manual must be followed.
KEEP THE MANUALS
The installation manual and user manual are stored by
the customer for clarification during use and for, e.g.
service.
WARNING!
If you smell gas, immediately switch off the gas supply. Turn off the fireplace at the stopcock and main electrical switch.
Ventilate the room by opening windows and doors. Do not use electrical appliances or switches in the vicinity of the
fireplace. The gas supply may not be reconnected until an authorised installer has examined the fireplace and approved
it.
NOTE!
For LPG, the installed regulator must allow the inlet pressure given on the information label. An authorised installer must
size the pipe to ensure the correct gas pressure and flow rate.
INTRODUCTION
INFORMATION LABEL
All RAIS gas fireplaces have an information label which
states the fireplace’s gas type, gas pressure, power,
etc.
The information label is laid on top of the gas fireplace
on delivery. Position the information label with the
GV60 Combination Valve and receiver for easy
access so that the authorised installer can check the
information.
The information label must be used during installation
for setting and checking gas pressure.
There is a larger version of the information label on
page 53.